Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Prussian Blue Modified Submicron Structured Gold Electrodes for Amperometric Hydrogen Peroxide Sensing

Lu, S.-Y., Chen, Y., Fang, X., & Feng, X. (2018). Prussian Blue Modified Submicron Structured Gold Electrodes for Amperometric Hydrogen Peroxide Sensing. Electroanalysis, 30(3), 583-592. doi:10.1002/elan.201700754.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Lu, Si-Yuan1, 2, Autor           
Chen, Yihao1, 2, Autor           
Fang, Xufei1, 2, 3, Autor           
Feng, Xue1, 2, Autor           
Affiliations:
1AML, School of Aerospace Engineering, Tsinghua University, Beijing, China, persistent22              
2Center for Advanced Mechanics and Materials, Tsinghua University, Beijing, China, persistent22              
3Nanotribology, Structure and Nano-/ Micromechanics of Materials, Max-Planck-Institut für Eisenforschung GmbH, Max Planck Society, ou_1863402              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In this work, we present a simple and effective approach for fabricating sub-micron structured gold (SM−Au) electrodes by chemically etching the magnetron co-sputtered gold film in KI solution for certain time. Such electrodes with a large surface area to volume ratio were used as the matrix for electrochemical deposition of Prussian blue (PB) to develop an electrochemical hydrogen peroxide sensor. Experimental characterization using scanning electron microscope and atomic force microscope shows that the thickness of PB layer on SM−Au electrode is around 140 nm, and is composited with cubic PB nanocrystals. The electrochemical performance of the designed sensor, studied using cyclic voltammograms and chronoamperometry methods, suggests that the sensor based on SM−Au/PB electrode presents the direct electron transfer of PB particle towards SM−Au film, and exhibits fast response, wide linearity, low detection limit and high stability. Under the optimized conditions, the sensitivity of the developed sensor for the detection of H2O2 reaches the value of 512 mA cm−2 M−1 with a linear range from 1 μM to 4.5 mM. © 2018 Wiley-VCH Verlag GmbH Co. KGaA, Weinheim

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2018-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/elan.201700754
BibTex Citekey: Lu2018583
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Electroanalysis
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Weinheim, Germany : Wiley-VCH
Seiten: - Band / Heft: 30 (3) Artikelnummer: - Start- / Endseite: 583 - 592 Identifikator: ISSN: 1040-0397
CoNE: https://pure.mpg.de/cone/journals/resource/954925587333