English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  High-resolution colocalization of single dye molecules by fluorescence lifetime imaging microscopy

Heilemann, M., Herten, D. P., Heintzmann, R., Cremer, C., Mueller, C., Tinnefeld, P., et al. (2002). High-resolution colocalization of single dye molecules by fluorescence lifetime imaging microscopy. Analytical Chemistry, 74(14), 3511-3517. Retrieved from http://pubs.acs.org/doi/pdfplus/10.1021/ac025576g.

Item is

Files

show Files
hide Files
:
16508.pdf (Publisher version), 0B
 
File Permalink:
-
Name:
16508.pdf
Description:
-
OA-Status:
Visibility:
Restricted (UNKNOWN id 303; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Heilemann, M., Author
Herten, D. P., Author
Heintzmann, R.1, Author           
Cremer, C., Author
Mueller, C., Author
Tinnefeld, P., Author
Weston, K. D., Author
Wolfrum, J., Author
Sauer, M., Author
Affiliations:
1Department of Molecular Biology, MPI for biophysical chemistry, Max Planck Society, ou_578628              

Content

show
hide
Free keywords: -
 Abstract: Conventional fluorescence microscopy can be used to determine the positions of objects in space when those objects are separated by distances greater than several hundred nanometers, as restricted by the diffraction limit of light. Fluorescence microscopy/spectroscopy based on fluorescence resonance energy- transfer techniques can be used to measure separation distances below similar to10 nm. To fill the gap between these fundamental limits, we have developed an alternative technique for high-resolution colocalization of fluorescent dyes. The technique is based on fluorescence lifetime imaging. Under favorable conditions, the method can be used to distinguish, and to measure the distance between, two dye molecules that are less than 30 nm apart. To demonstrate the method, lifetime images of a mixture of Cy5 and JF9 (rhodamine derivative) molecules statistically adsorbed on a glass surface were acquired and analyzed. Since these two molecular species differ in fluorescence lifetime (for Cy5, tau(f) = 2.0 us, and for JF9, tau(f) = 4.0 ns), it is possible to assign the contribution of fluorescence of the two dye types to each image pixel using a pattern recognition technique. Since both dye types can be excited using the same laser wavelength, the measurement is free of chromatic aberrations. The results presented demonstrate the first high-precision distance measurements between single conventional fluorescent dyes based solely on fluorescence lifetime.

Details

show
hide
Language(s): eng - English
 Dates: 2002-07-15
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 16508
URI: http://pubs.acs.org/doi/pdfplus/10.1021/ac025576g
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Analytical Chemistry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 74 (14) Sequence Number: - Start / End Page: 3511 - 3517 Identifier: -