English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  The application of a new sampling theorem for non-bandlimited signals on the sphere: Improving the recovery of crossing fibers for low b-value acquisitions

Deslauriers-Gauthier, S., Marziliano, P., Paquette, M., & Descoteaux, M. (2016). The application of a new sampling theorem for non-bandlimited signals on the sphere: Improving the recovery of crossing fibers for low b-value acquisitions. Medical Image Analysis, 30, 46-59. doi:10.1016/j.media.2016.01.002.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Deslauriers-Gauthier, Samuel1, Author
Marziliano, Pina1, Author
Paquette, Michael1, Author           
Descoteaux, Maxime1, Author
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: Diffusion MRI; Finite rate of innovation; Peak detection; Spherical deconvolution
 Abstract: Recent development in sampling theory now allows the sampling and reconstruction of certain non-bandlimited functions on the sphere, namely a sum of weighted Diracs. Because the signal acquired in diffusion Magnetic Resonance Imaging (dMRI) can be modeled as the convolution between a sampling kernel and two dimensional Diracs defined on the sphere, these advances have great potential in dMRI. In this work, we introduce a local reconstruction method for dMRI based on a new sampling theorem for non-bandlimited signals on the sphere. This new algorithm, named Spherical Finite Rate of Innovation (SFRI), is able to recover fibers crossing at very narrow angles with little dependence on the b-value. Because of its parametric formulation, SFRI can distinguish crossing fibers even when using a DTI-like acquisition (≈32 directions). This opens new perspective for low b-value and low number of gradient directions diffusion acquisitions and tractography studies. We evaluate the angular resolution of SFRI using state of the art synthetic data and compare its performance using in-vivo data. Our results show that, at low b-values, SFRI recovers crossing fibers not identified by constrained spherical deconvolution. We also show that low b-value results obtained using SFRI are similar to those obtained with constrained spherical deconvolution at a higher b-value.

Details

show
hide
Language(s): eng - English
 Dates: 2015-11-132015-01-242016-01-072016-01-202016-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Medical Image Analysis
  Other : Med. Image Anal.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London : Elsevier
Pages: - Volume / Issue: 30 Sequence Number: - Start / End Page: 46 - 59 Identifier: ISSN: 1361-8415
CoNE: https://pure.mpg.de/cone/journals/resource/954927741859