  New Design of Electrostatic Mirror Actuators for Application in High-Precision Interferometry

Wittel, H., Hild, S., Bergmann, G., Danzmann, K., & Strain, K. A. (2015). New Design of Electrostatic Mirror Actuators for Application in High-Precision Interferometry. Classical and quantum gravity, 32(17): 175021. doi:10.1088/0264-9381/32/17/175021.

Item is

Files

show Files
hide Files
:
1411.3853.pdf (Preprint), 4MB
Name:
1411.3853.pdf
Description:
File downloaded from arXiv at 2015-10-15 10:24
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
:
document(4).pdf (Any fulltext), 2MB
Name:
document(4).pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Wittel, H.1, Author           
Hild, S.1, Author           
Bergmann, G.1, Author           
Danzmann, K.1, Author           
Strain, K. A.1, Author           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Content

show
hide
Free keywords: Physics, Optics, physics.optics, Astrophysics, Instrumentation and Methods for Astrophysics, astro-ph.IM, Physics, Instrumentation and Detectors, physics.ins-det
 Abstract: We describe a new geometry for electrostatic actuators to be used in sensitive laser interferometers. The arrangement consists of two plates at the sides of the mirror (test mass), and therefore does not reduce its clear aperture as a conventional electrostatic drive (ESD) would do. Using the sample case of the AEI-10m prototype interferometer, we investigate the actuation range and influences of relative misalignment of the ESD plates in respect to the test mass. We find that in the case of the AEI-10 m prototype interferometer, this new kind of ESD could provide a range of 0.28 micrometer when operated at a voltage of 1 kV. In addition, the geometry presented is shown to provide a reduction factor of about 100 in the magnitude of actuator motion coupling to test mass displacement. We show that therefore in the specific case of the AEI-10m interferometer it is possible to mount the ESD actuators directly on the optical table, without spoiling the seismic isolation performance of the triple stage suspension of the main test masses.

Details

show
hide
Language(s):
 Dates: 2014-11-142015
 Publication Status: Issued
 Pages: 10 pages, 9 figures
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Classical and quantum gravity
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Bristol, U.K. : Institute of Physics
Pages: - Volume / Issue: 32 (17) Sequence Number: 175021 Start / End Page: - Identifier: ISSN: 0264-9381
CoNE: https://pure.mpg.de/cone/journals/resource/954925513480_1