English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain

Paech, D., Schuenke, P., Koehler, C., Windschuh, J., Mundiyanapurath, S., Bickelhaupt, S., et al. (2017). T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain. Radiology, 285(3), 914-922. doi:10.1148/radiol.2017162351.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Paech, D, Author
Schuenke, P, Author
Koehler, C, Author
Windschuh, J, Author
Mundiyanapurath, S, Author
Bickelhaupt, S, Author
Bonekamp, D, Author
Bäumer, P, Author
Bachert, P, Author
Ladd, ME, Author
Bendszus, M, Author
Wick, W, Author
Unterberg, A, Author
Schlemmer, HP, Author
Zaiss, M1, 2, Author           
Radbruch, A, Author
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange–sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20 d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59) was significantly increased compared with that in white matter tissue (DGEρ = 0.65) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08) (P < .0001). Conclusion T1ρ-weighted DGE MR imaging in healthy volunteers and patients with newly diagnosed, untreated glioblastoma enabled visualization of brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue.

Details

show
hide
Language(s):
 Dates: 2017-12
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1148/radiol.2017162351
BibTex Citekey: PaechSKWMBBBBLBWUSZR2017
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Radiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 285 (3) Sequence Number: - Start / End Page: 914 - 922 Identifier: -