  Comparison of different assessment quantities to evaluate lead electromagnetic model for radio frequency energy-induced heating

Kozlov, M., & Kainz, W. (2019). Comparison of different assessment quantities to evaluate lead electromagnetic model for radio frequency energy-induced heating. IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology. doi:10.1109/JERM.2019.2938166.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Kozlov, Mikhail1, Author           
Kainz , Wolfgang2, Author
Affiliations:
1Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              
2Office of Science and Engineering Laboratories; Division of Biomedical Physics; Silver Spring, MD, ou_persistent22              

Content

show
hide
Free keywords: electromagnetics; radio frequency safety; heating; active implantable medical devices; transfer functions
 Abstract: To prevent tissue damage near an active implantable medical device (AIMD), the radio frequency energy-induced heating must be estimated for all possible clinical scenarios in patients undergoing magnetic resonance imaging. Four quantities, namely 1) the net dissipated power around an electrode of an AIMD, 2) the net temperature increase, 3) the current flowing from the lead to the electrode, and 4) the net specific absorption rate (SAR) increase were numerically compared for a set of leads to evaluate the analytical lead electromagnetic model (LEM) with respect to radio frequency energy-induced heating. The set included 32 single electrode leads with straight and helical wires. The LEMs were obtained and validated with 3D electromagnetic and thermal co-simulations at 128 MHz. A shift of the position of temperature or SAR sensor from the electrode tip to the electrode pedestal resulted in a decrease of the linear regression coefficient of determination for the LEM calibration factors. Behavior of different assessment quantities in terms of sensitivity of sensor location significantly varied between leads with the helical and straight wires. In conclusion, utilization of analysis made for generic leads with straight wire can be significantly misleading for the prediction of results for leads with helical wires.

Details

show
hide
Language(s): eng - English
 Dates: 2019-08-28
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1109/JERM.2019.2938166
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : IEEE
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: - Identifier: ISSN: 2469-7249
CoNE: https://pure.mpg.de/cone/journals/resource/2469-7249