Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Non-Matrix-Matched Calibration for the Multi-Element Analysis of Geological and Environmental Samples Using 200 nm Femtosecond LA-ICP-MS: A Comparison with Nanosecond Lasers

Jochum, K. P., Stoll, B., Weis, U., Jacob, D. E., Mertz-Kraus, R., & Andreae, M. O. (2014). Non-Matrix-Matched Calibration for the Multi-Element Analysis of Geological and Environmental Samples Using 200 nm Femtosecond LA-ICP-MS: A Comparison with Nanosecond Lasers. Geostandards and Geoanalytical Research, 38(3), 265-292. doi:10.1111/j.1751-908X.2014.12028.x.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Jochum, Klaus Peter1, Autor           
Stoll, Brigitte1, Autor           
Weis, Ulrike1, Autor           
Jacob, Dorrit E.2, Autor
Mertz-Kraus, Regina2, Autor
Andreae, Meinrat O.1, Autor           
Affiliations:
1Biogeochemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826286              
2external, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: LA-ICP-MS is one of the most promising techniques for in situ analysis of geological and environmental samples. However, there are some limitations with respect to measurement accuracy, in particular for volatile and siderophile/chalcophile elements, when using non-matrix-matched calibration. We therefore investigated matrix-related effects with a new 200nm femtosecond (fs) laser ablation system (NWRFemto200) using reference materials with different matrices and spot sizes from 10 to 55m. We also performed similar experiments with two nanosecond (ns) lasers, a 193nm excimer (ESI NWR 193) and a 213nm Nd:YAG (NWR UP-213) laser. The ion intensity of the 200nm fs laser ablation was much lower than that of the 213nm Nd:YAG laser, because the ablation rate was a factor of about 30 lower. Our experiments did not show significant matrix dependency with the 200nm fs laser. Therefore, a non-matrix-matched calibration for the multi-element analysis of quite different matrices could be performed. This is demonstrated with analytical results from twenty-two international synthetic silicate glass, geological glass, mineral, phosphate and carbonate reference materials. Calibration was performed with the certified NIST SRM 610 glass, exclusively. Within overall analytical uncertainties, the 200nm fs LA-ICP-MS data agreed with available reference values.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2014-09
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Geostandards and Geoanalytical Research
  Andere : Geostand. Geoanal. Res.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Vandoeuvre-lès-Nancy : Association scientifique pour la géologie et ses applications with the assistance of the Centre national de la recherche scientifique
Seiten: - Band / Heft: 38 (3) Artikelnummer: - Start- / Endseite: 265 - 292 Identifikator: ISSN: 1639-4488
CoNE: https://pure.mpg.de/cone/journals/resource/954925476486