  Simulation of Flow-Driven Adiabatic Inversion in Dual Coil Continuous ASL at 9.4 T

Bause, J., Scheffler, K., & Pohmann, R. (2015). Simulation of Flow-Driven Adiabatic Inversion in Dual Coil Continuous ASL at 9.4 T. Magnetic Resonance Materials in Physics, Biology and Medicine, 28(Supplement 1), S367-S368.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Bause, J1, Autor           
Scheffler, K1, Autor           
Pohmann, R1, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose/Introduction: Continuous ASL with labeling coils placed at the subject´s neck (DC-CASL, [1]) has a high sensitivity [2], does not suffer from magnetization transfer effects and leads to lower power deposition than any other CASL technique. The latter makes it especially interesting for ultra-high field applications where the TR in ASL is limited by the high SAR evoked by the inversion. So far, simulations of the efficiency were performed for field strengths up to 3 T [2–3]. However, the shorter T2 of arterial blood at 9.4 T requires reassessing of the labeling process at this field strength. Subjects and Methods: Bloch simulations were performed in Matlab for different blood velocities (vblood = 0.01 - 1 m/s), transmit fields (B1 +=2.5, 3.5 and 4.5 lT) and gradients (Gz = 0-10 mT/m) assuming T1 = 2400 ms [5], T2 = 30 ms [6] at 9.4 T. For comparison, calculations were also performed with 3 T relaxation times (T1 = 1330 s [7], T2 = 250 ms [8]). The efficiencies of cases with an adiabaticity \1 were set to zero. In order to take the temporally varying blood volume and the parabolic velocity profile into account, the total efficiency was calculated as described in Ref. [2]. Two flow weighting models were investigated: I. A two period model [2]; II. A detailed representation of vblood over time adapted from [4]. A constant transmit field was assumed since the influences of the B1 + shape of a surface coil on the inversion are negligible [3]. Results: Figure 1a shows the overall efficiencies for three transmit field strengths at 9.4 T and Fig. 1b the corresponding values at 3 T. For a given B1 +, the more detailed model II (b) requires slightly stronger gradients than model I (a) to achieve the optimal performance. The flow weighted inversion efficiency during the cardiac circle is depicted in Fig. 2. Table 1 comprises the efficiencies for some B1 +/Gz combinations. Discussion/Conclusion: In comparison to 3 T, stronger gradients are required for labeling at ultra-high field. However the lower efficiency will be compensated by the longer longitudinal relaxation time at 9.4 T. One possibility to reduce the T2 effect may be the utilization of local non-linear gradient coils [3]. The strong dependency on vblood complicates the quantification of DC-CASL especially in patients.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2015-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-015-0489-0
BibTex Citekey: BauseSP2015
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 32nd Annual Scientific Meeting ESMRMB 2015
Veranstaltungsort: Edinburgh, UK
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 28 (Supplement 1) Artikelnummer: - Start- / Endseite: S367 - S368 Identifikator: -