Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Feasibility of functional MRI at ultralow magnetic field via changes in cerebral blood volume

Buckenmaier, K., Pedersen, A., SanGiorgio, P., Scheffler, K., Clarke, J., & Inglis, B. (2019). Feasibility of functional MRI at ultralow magnetic field via changes in cerebral blood volume. Poster presented at 21st ISMAR - 15th EUROMAR Jount Conference (EUROISMAR 2019), Berlin, Germany.

Item is

Urheber

einblenden:
ausblenden:
 Urheber:
Buckenmaier, K1, 2, Autor           
Pedersen, A, Autor
SanGiorgio, P, Autor
Scheffler, K1, 2, Autor           
Clarke, J, Autor
Inglis, B, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We investigate the feasibility of performing functional MRI (fMRI) at ultralow field (ULF) with a Superconducting Quantum Interference Device (SQUID), as used for detecting magnetoencephalography (MEG) signals from the human head. While there is negligible magnetic susceptibility variation to produce blood oxygenation level-dependent (BOLD) contrast at ULF, changes in cerebral blood volume (CBV) may be a sensitive mechanism for fMRI given the five-fold spread in spin-lattice relaxation time (T1) values across the constituents of the human brain. We undertook simulations of functional signal strength for a simplified brain model involving activation of a primary cortical region in a manner consistent with a blocked task experiment. Our simulations involve measured values of T1 at ULF (130 μT) and experimental parameters for the performance of an ULFMRI scanner with a noise level of 0.1 fT/Hz-1/2 and a prepolarizing field of 200 mT. Under ideal experimental conditions we predict a functional signal-to-noise ratio of between 3.1 and 7.1 for an imaging time of 30 min, or between 1.5 and 3.5 for a blocked task experiment lasting 7.5 min. Our simulations suggest it may be feasible but challenging to perform fMRI using a ULFMRI system designed to perform MRI and MEG in situ.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2019-08
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: -
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 21st ISMAR - 15th EUROMAR Jount Conference (EUROISMAR 2019)
Veranstaltungsort: Berlin, Germany
Start-/Enddatum: 2019-08-25 - 2019-08-30

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 21st ISMAR - 15th EUROMAR Jount Conference (EUROISMAR 2019)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: P552 Start- / Endseite: 758 Identifikator: -