English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Optimization of pulse train presaturation for CEST imaging in clinical scanners

Schmitt, B., Zaiss, M., Zhou, J., & bachert, P. (2011). Optimization of pulse train presaturation for CEST imaging in clinical scanners. Magnetic Resonance in Medicine, 65(6), 1620-1629. doi:10.1002/mrm.22750.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Schmitt, B, Author
Zaiss, M1, Author           
Zhou, J, Author
bachert, P, Author
Affiliations:
1Department of Medical Physics in Radiology, Deutsches Krebsforschungszentrum (DKFZ, German Cancer Research Center), Heidelberg, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Chemical exchange saturation transfer (CEST) imaging depends on the performance of radiofrequency saturation during the experiment. Scanner specifications, in particular limited pulse width and duty‐cycle, and specific absorption rate guidelines restrict the full exploitation of CEST effects in clinical MR systems. The purpose of this study was to optimize techniques for effective pulse train presaturation for CEST imaging in a whole‐body MR scanner. Theoretical analysis and simulations of the spectral properties of radiofrequency pulse trains demonstrated the significance of pulse width τP and interpulse delay τD for effective and selective labeling of a chemically exchanging proton pool. CEST experiments with model solutions, e.g., creatine dissolved in water, showed best performance of pulse trains with τP = τD = 100 msec, regarding minimum direct water saturation in z‐spectra and distinct magnetization transfer ratio asymmetry that can be determined quantitatively. Saturation efficiency of trains of Gaussian‐shaped radiofrequency pulses using this timing was evaluated in MR imagers with field strengths of 1.5, 3, and 7 T. The proposed saturation pulse train does not require hardware modifications, offers low specific absorption rate, and can be used in a standard clinical setup.

Details

show
hide
Language(s):
 Dates: 2011-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.22750
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 65 (6) Sequence Number: - Start / End Page: 1620 - 1629 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149