Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Multiple interleaved mode saturation (MIMOSA) for B1 + inhomogeneity mitigation in chemical exchange saturation transfer

Liebert, A., Zaiss, M., Gumbrecht, R., Tkotz, K., Linz, P., Schmitt, B., et al. (2019). Multiple interleaved mode saturation (MIMOSA) for B1 + inhomogeneity mitigation in chemical exchange saturation transfer. Magnetic Resonance in Medicine, 82(2), 693-705. doi:10.1002/mrm.27762.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Liebert, A, Autor
Zaiss, M1, 2, Autor           
Gumbrecht, R, Autor
Tkotz, K, Autor
Linz, P, Autor
Schmitt, B, Autor
Laun, FB, Autor
Doerfler, A, Autor
Uder, M, Autor
Nagel, AM, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: PURPOSE: To mitigate B+1 inhomogeneity in quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7 Tesla) using a parallel transmit system.
METHODS: Multiple interleaved mode saturation employs interleaving of 2 complementary phase sets during the saturation pulse train. Phase differences of 45° (first mode) and 90° (second mode) between 2 adjacent transmitter coil channels are used. The influence of the new saturation scheme on the CEST contrast was analyzed using Bloch-McConnell simulations. The presented method was verified in phantom and in vivo measurements of the healthy human brain. The relayed nuclear Overhauser effect was evaluated, and the inverse magnetic transfer ratio metric was calculated. Results were compared to a published B+1 correction method. All measurements were conducted on a whole-body 7 Tesla MRI system using an 8 transmitter and 32 receiver channel head coil.
RESULTS: Simulations showed that the inverse magnetic transfer ratio metric contrast of relayed nuclear Overhauser effect shows a smaller dependency on the relative amplitudes of the 2 different modes than the contrasts of Cr and amide proton transfer. Measurements of an egg white phantom showed markedly improved homogeneity compared to the uncorrected inverse magnetic transfer ratio metric (relayed nuclear Overhauser effect) images and slightly improved results compared to B+1 corrected images. In vivo multiple interleaved mode saturation images showed similar contrast compared to B+1 corrected images.
CONCLUSION: Multiple interleaved mode saturation can be used as a simple method to mitigate B+1 inhomogeneity effects in CEST MRI at ultra-high magnetic field strengths. Compared to previous B+1 correction methods, acquisition time can be reduced because an additional scan, usually required for B+1 correction, can be omitted.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2019-042019-08
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.27762
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 82 (2) Artikelnummer: - Start- / Endseite: 693 - 705 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149