English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Combination of surface and "vertical" loop elements improves receive performance of a human head transceiver array at 9.4 T

Avdievich, N., Giapitzakis, I., Pfrommer, A., Borbath, T., & Henning, A. (2018). Combination of surface and "vertical" loop elements improves receive performance of a human head transceiver array at 9.4 T. NMR in Biomedicine, 31(2), 1-13. doi:10.1002/nbm.3878.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Avdievich, NI1, 2, 3, Author           
Giapitzakis, IA1, 2, 3, Author           
Pfrommer, A1, 3, Author           
Borbath, T1, 3, Author           
Henning, A1, 2, 3, Author           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
3Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Ultra-high-field (UHF, ≥7 T) human magnetic resonance imaging (MRI) provides undisputed advantages over low-field MRI (≤3 T), but its development remains challenging because of numerous technical issues, including the low efficiency of transmit (Tx) radiofrequency (RF) coils caused by the increase in tissue power deposition with frequency. Tight-fit human head transceiver (TxRx) arrays improve Tx efficiency in comparison with Tx-only arrays, which are larger in order to fit multi-channel receive (Rx)-only arrays inside. A drawback of the TxRx design is that the number of elements in an array is limited by the number of available high-power RF Tx channels (commonly 8 or 16), which is not sufficient for optimal Rx performance. In this work, as a proof of concept, we developed a method for increasing the number of Rx elements in a human head TxRx surface loop array without the need to move the loops away from a sample, which compromises the array Tx performance. We designed and constructed a prototype 16-channel tight-fit array, which consists of eight TxRx surface loops placed on a cylindrical holder circumscribing a head, and eight Rx-only vertical loops positioned along the central axis (parallel to the magnetic field B0) of each TxRx loop, perpendicular to its surface. We demonstrated both experimentally and numerically that the addition of the vertical loops has no measurable effect on the Tx efficiency of the array. An increase in the maximum local specific absorption rate (SAR), evaluated using two human head voxel models (Duke and Ella), measured 3.4 or less. At the same time, the 16-element array provided 30 improvement of central signal-to-noise ratio (SNR) in vivo relative to a surface loop eight-element array. The novel array design also demonstrated an improvement in the parallel Rx performance in the transversal plane. Thus, using this method, both the Rx and Tx performance of the human head array can be optimized simultaneously.

Details

show
hide
Language(s):
 Dates: 2018-02
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/nbm.3878
BibTex Citekey: AvdievichGPBH2017
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NMR in Biomedicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 31 (2) Sequence Number: - Start / End Page: 1 - 13 Identifier: eDoc: e3878