English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Measurement of the positronium 1 3S1–2 3S1 interval by continuous-wave two-photon excitation

Fee, M. S., Chu, S., Mills, A. P., Chichester, R. J., Zuckerman, D. M., Shaw, E. D., et al. (1993). Measurement of the positronium 1 3S1–2 3S1 interval by continuous-wave two-photon excitation. Physical Review A, 48(1), 192-219. doi:10.1103/PhysRevA.48.192.

Item is

Files

show Files
hide Files
:
372224.pdf (Publisher version), 6MB
Name:
372224.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
eDoc_access: PUBLIC
License:
-

Locators

show

Creators

show
hide
 Creators:
Fee, Michale S.1, Author
Chu, Steven, Author
Mills, A. P., Author
Chichester, R. J., Author
Zuckerman, D. M.2, 3, Author
Shaw, E. D., Author
Danzmann, Karsten2, Author           
Affiliations:
1External Organizations, ou_persistent13              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
3AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24009              

Content

show
hide
Free keywords: -
 Abstract: Positronium is the quasistable bound system consisting of an electron and its antiparticle, the positron. Its energy levels can be explained to a high degree of accuracy by the electromagnetic interaction, affording an ideal test of the quantum electrodynamic (QED) theory of bound systems. We have measured the 1 3S1–2 3S1 interval in positronium by Doppler-free two-photon spectroscopy to be 1 233 607 216.4±3.2 MHz. We employ continous-wave (cw) excitation to eliminate the problems inherent with pulsed laser measurements of nonlinear transitions. Positronium (Ps) atoms generated in vacuum are excited to the 2S state using cw laser light built up to 2.5 kW circulating power in a resonant Fabry-Pérot cavity. The excited-state atoms are photoionized using a pulsed laser at 532 nm, and the liberated positrons counted as the cw laser is tuned relative to a reference line in tellurium (Te2) molecular vapor. The fit of a detailed theoretical model to the measured line shape determines the Ps resonance frequency relative to the Te2 reference line. The Monte Carlo model includes details of the excitation and detection geometry, the Ps velocity distribution, and the dynamic Stark shift, and gives excellent agreement with the measured line shapes. The quoted 2.6 parts per billion (ppb) uncertainty is dominated by the measurement of the Ps line center relative to the Te2 reference line, with a 1.0-ppb contribution from a recent calibration of our Te2 cell relative to the hydrogen 1S-2S transition frequency. The measurement is in excellent agreement with theory and sufficiently accurate to provide a test of the as-yet-uncalculated α4R∞ QED correction. Our measurement tests the α2R∞ QED contributions to the energy of the 1 3S1 and 2 3S1 states to 3.5 parts in 105.

Details

show
hide
Language(s):
 Dates: 1993-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physical Review A
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 48 (1) Sequence Number: - Start / End Page: 192 - 219 Identifier: ISSN: 1094-1622