  Biopsy needle tips with markers: MR compatible needles for high-precision needle tip positioning

Müller-Bierl, B., Martirosian, P., Graf, H., Boss, A., König, C., Pereira, P., et al. (2008). Biopsy needle tips with markers: MR compatible needles for high-precision needle tip positioning. Medical Physics, 35(6), 2273-2278. doi:10.1118/1.2919082.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Müller-Bierl, B1, 2, Autor           
Martirosian, P, Autor
Graf, H, Autor
Boss, A, Autor
König, C, Autor
Pereira, P, Autor
Schick, F, Autor
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Needle tip visualization is of high importance in magnetic resonance imaging (MRI) guided interventional procedures, for example for taking biopsies from suspicious lesions in the liver or kidney. The exact position of the needle tip is often obscured by image artifacts arising from the magnetic properties of the needle. The authors investigated two special biopsy needle tip designs using diamagnetic coatings. For common interventional MR sequences, the needle tip can be identified in the MR image by several equidistant dark spots arranged along a straight line. A dotted instead of a solid line allows for an improved control of the movement of the needle, not only if the needle is tilted toward the imaging plane, but also if the needle leaves an empty canal with signal extinction, which cannot be distinguished from the needle material itself. With the proposed design the position of the needle tip can be estimated with a precision of approximately 1 mm using conventional FLASH, FISP, and TSE sequences, as use
d for interventional MR. Furthermore, the size of the biopsy probe can be estimated from the artifact. In using needles with a properly designed tip coating, taking biopsies under MR control is beginning to be greatly simplified. The approach to design artifacts using diamagnetic material in combination with paramagnetic material paves the way toward new instruments and implants, suitably tailored to the needs of the interventional radiologist.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1118/1.2919082
BibTex Citekey: 5440
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Medical Physics
  Andere : Med. Phys.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, etc. : Published for the American Association of Physicists in Medicine by the American Institute of Physics
Seiten: - Band / Heft: 35 (6) Artikelnummer: - Start- / Endseite: 2273 - 2278 Identifikator: ISSN: 0094-2405
CoNE: https://pure.mpg.de/cone/journals/resource/991042742884000