English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Dynamic fluorescence anisotropy imaging microscopy in the frequency domain (rFLIM)

Clayton, A. H. A., Hanley, Q. S., Arndt-Jovin, D. J., Subramaniam, V., & Jovin, T. M. (2002). Dynamic fluorescence anisotropy imaging microscopy in the frequency domain (rFLIM). Biophysical Journal, 83(3), 1631-1649. Retrieved from http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B94RW-4V466X4-19-1&_cdi=56421&_user=38661&_pii=S0006349502739325&_origin=search&_coverDate=09%2F30%2F2002&_sk=999169996&view=c&wchp=dGLbVzz-zSkWb&md5=e1c0a00e6b64fa5bfba2ba24581b92e2&ie=/sdarticle.pdf.

Item is

Files

show Files
hide Files
:
16647.pdf (Publisher version), 0B
Name:
16647.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Clayton, A. H. A.1, Author           
Hanley, Q. S.2, Author
Arndt-Jovin, D. J.1, Author           
Subramaniam, V.1, Author           
Jovin, T. M.1, Author           
Affiliations:
1Department of Molecular Biology, MPI for biophysical chemistry, Max Planck Society, ou_578628              
2Max Planck Society, ou_persistent13              

Content

show
hide
Free keywords: Differential phase fluorometry; Polarization microscopy; Rotational diffusion; Backbone dynamics; Living cells; Spectroscopy; Protein; Depolarization; Motion; State
 Abstract: We describe a novel variant of fluorescence lifetime imaging microscopy (FLIM), denoted anisotropy-FLIM or rFLIM, which enables the wide-field measurement of the anisotropy decay of fluorophores on a pixel-by-pixel basis. We adapted existing frequency-domain FLIM technology for rFLIM by introducing linear polarizers in the excitation and emission paths. The phase delay and intensity ratios (AC and DC) between the polarized components of the fluorescence signal are recorded, leading to estimations of rotational correlation times and limiting anisotropies. Theory is developed that allows all the parameters of the hindered rotator model to be extracted from measurements carried out at a single modulation frequency. Two- dimensional image detection with a sensitive CCD camera provides wide-field imaging of dynamic depolarization with parallel interrogation of different compartments of a complex biological structure such as a cell. The concepts and technique of rFLIM are illustrated with a fluorophore-solvent (fluorescein-glycerol) system as a model for isotropic rotational dynamics and with bacteria expressing enhanced green fluorescent protein (EGFP) exhibiting depolarization due to homotransfer of electronic excitation energy (emFRET). The frequency-domain formalism was extended to cover the phenomenon of emFRET and yielded data consistent with a concentration depolarization mechanism resulting from the high intracellular concentration of EGFP. These investigations establish rFLIM as a powerful tool for cellular imaging based on rotational dynamics and molecular proximity.

Details

show
hide
Language(s): eng - English
 Dates: 2005-04-122002-09
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Biophysical Journal
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 83 (3) Sequence Number: - Start / End Page: 1631 - 1649 Identifier: -