Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Interferometer readout-noise below the Standard Quantum Limit of a membrane

Westphal, T., Friedrich, D., Kaufer, H., Yamamoto, K., Gossler, S., Mueller-Ebhardt, H., et al. (2012). Interferometer readout-noise below the Standard Quantum Limit of a membrane. Physical Review A, 85: 063806. doi:10.1103/PhysRevA.85.063806.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1111.7236 (Preprint), 2MB
Name:
1111.7236
Beschreibung:
File downloaded from arXiv at 2013-03-27 09:59
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
PRA85_063806.pdf (beliebiger Volltext), 476KB
Name:
PRA85_063806.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Westphal, Tobias1, Autor           
Friedrich, Daniel1, Autor           
Kaufer, Henning1, Autor           
Yamamoto, Kazuhiro1, Autor           
Gossler, Stefan1, Autor           
Mueller-Ebhardt, Helge1, Autor           
Danilishin, Stefan L., Autor
Khalili, Farid Ya., Autor
Danzmann, Karsten1, Autor           
Schnabel, Roman1, Autor           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Physics, Optics, physics.optics,Quantum Physics, quant-ph
 Zusammenfassung: Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of 3E-16 m/sqrt(Hz) at frequencies around the fundamental resonance of a SiN_x membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This reduction is significantly higher than those of previous works with nano-wires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and conclude that neither our nor previous experiments achieved a total noise spectral density as low as the SQL.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-11-302012
 Publikationsstatus: Erschienen
 Seiten: 5
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: arXiv: 1111.7236
DOI: 10.1103/PhysRevA.85.063806
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review A
  Andere : Phys. Rev. A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : Published by the American Physical Society through the American Institute of Physics
Seiten: - Band / Heft: 85 Artikelnummer: 063806 Start- / Endseite: - Identifikator: ISSN: 1050-2947
CoNE: https://pure.mpg.de/cone/journals/resource/954925225012_2