English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Development of a long trace profiler in situ at National Synchrotron Radiation Research Center

Lin, S.-W., Wang, D.-J., Fu, H.-W., Tsai, H.-M., Hua, C.-Y., Kuo, C.-Y., et al. (2019). Development of a long trace profiler in situ at National Synchrotron Radiation Research Center. Review of Scientific Instruments, 90(2): 021716, pp. 1-7. doi:10.1063/1.5055634.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Lin, Shang-Wei1, Author
Wang, Duan-Jen1, Author
Fu, Huang-Wen1, Author
Tsai, Huang-Ming1, Author
Hua, Chih-Yu1, Author
Kuo, Chang-Yang2, Author           
Hsu, Ming-Ying1, Author
Kao, Kai-Yang1, Author
Yin, Gung-Chian1, Author
Fung, Hok-Sum1, Author
Perng, Shen-Yaw1, Author
Chang, Chia-Feng1, Author
Affiliations:
1External Organizations, ou_persistent22              
2Physics of Correlated Matter, Max Planck Institute for Chemical Physics of Solids, Max Planck Society, ou_1863445              

Content

show
hide
Free keywords: -
 Abstract: To achieve an ultrahigh resolution of a beamline for soft X-rays at the Taiwan Photon Source (TPS), the profile of a highly precise grating is required at various curvatures. The slope error could be decreased to 0.1 mu rad (rms) at a thermal load with a specially designed bender having 25 actuators. In the meantime, a long-trace profiler (LTP) was developed in situ to monitor the grating profile under a thermal load; it consists of a moving optical head, an air-bearing slide, an adjustable stand, and a glass viewport on the vacuum chamber. In the design of this system, a test chamber with an interior mirror was designed to simulate the chamber in the beamline. To prevent an error induced from a commercial viewport, a precision glass viewport (150CF, flatness 1/150 lambda rms at 632.8 nm) was designed. The error induced from the slope error of the glass surface and the vacuum deformation was also simulated. The performance of the optical head of the LTP in situ (ISLTP) has been tested in the metrology laboratory. The sources of error of this LTP including the linearity and the glass viewport were corrected after the measurement. For the beamline measurement, an optical head was mounted outside the vacuum chamber; the measuring beam passed through the glass viewport to measure the grating profile in vacuum. The measurement of the LTP after correction of the above errors yielded a precision about 0.2 mu rad (rms). In a preliminary test, an ISLTP was used to measure the grating profile at soft X-ray beamline TPS45A. The measured profile was for the bending mechanism to optimize the slope profile. From the measured energy spectrum, the slope error of the grating was estimated with software for optical simulation to be about 0.3 mu rad (rms), consistent with our estimate of the ISLTP. In the future, it will be used to monitor the thermal bump under a large thermal load. In addition, an ISLTP was used to monitor the properties of optical elements-the twist and radius in the beamline during the installation phase. Published under license by AIP Publishing.

Details

show
hide
Language(s): eng - English
 Dates: 2019-02-192019-02-19
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000460095300017
DOI: 10.1063/1.5055634
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Review of Scientific Instruments
  Abbreviation : Rev. Sci. Instrum.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Melville, NY : AIP Publishing
Pages: - Volume / Issue: 90 (2) Sequence Number: 021716 Start / End Page: 1 - 7 Identifier: ISSN: 0034-6748
CoNE: https://pure.mpg.de/cone/journals/resource/991042742033452