Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Qualitative Comparison between In Vivo J-Resolved Semi-LASER at 3 T and 9.4 T

Murali Manohar, S., Giapitzakis, I., Borbáth, T., Gaertner, M., & Henning, A. (2017). Qualitative Comparison between In Vivo J-Resolved Semi-LASER at 3 T and 9.4 T. Poster presented at 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA.

Item is

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Murali Manohar, SV1, 2, Autor           
Giapitzakis, IA1, 2, Autor           
Borbáth, T1, 2, Autor           
Gaertner, M, Autor
Henning, A1, 2, Autor           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: J-resolved semi-LASER with maximum-echo sampling is optimized at 9.4T and compared with the same implementation at 3T in terms of SNR and spectral resolution. SODA scheme is appreciated for the sequence rather than the MC scheme. SNR at 9.4T (t1 steps: 85) was approximately 5.8 times greater than at 3T (t1 steps: 100) and strongly coupled peaks are well-resolved. However, the trade-off between SNR and spectral resolution is explained as lactate (1.32 ppm), a weakly-coupled metabolite, is better resolved at 3T. Higher band-width AFP pulses helped in almost vanishing the J-refocused peaks which made the J-resolved peaks clearly distinguishable. A few interesting downfield peaks and the doublet of NAA (7.82ppm) are observed.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2017-04-27
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: MuraliManoharGBGH2017
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017)
Veranstaltungsort: Honolulu, HI, USA
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017)
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: 3015 Start- / Endseite: - Identifikator: -