  Improving Spectral Quality in the Myocardium at 3T Using ECG- Triggered, Navigator-Gated Metabolite-Cycling along with Image-Based B0-Shimming

Fillmer, A., Cameron, D., Hock, A., Redpath, T., Frenneaux, M., Dawson, D., et al. (2013). Improving Spectral Quality in the Myocardium at 3T Using ECG- Triggered, Navigator-Gated Metabolite-Cycling along with Image-Based B0-Shimming. Magnetic Resonance Materials in Physics, Biology and Medicine, 26(Supplement 1), 62-63.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Meeting Abstract

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Fillmer, A, Autor
Cameron, D, Autor
Hock, A, Autor
Redpath, T, Autor
Frenneaux, M, Autor
Dawson, D, Autor
Henning, A1, 2, Autor           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: 1H MR Spectroscopy is a promising tool for investigating heart disease. To achieve a good spectral quality, challenges like cardiac and respiratory motion and complex B0-field inhomogeneities must be addressed. The combination of image-based B0-shimming[1], ECG-triggering and navigator-gating[2] along with frequency-alignment and phase-correction of metabolite-cycled )[3], non-water-suppressed MRS[4] data, is used to demonstrate the feasibility of metabolite-cycling in the heart. Measurements were performed in five volunteers(21y- 39y) on an Achieva 3T system with a 6-element cardiac coil (Philips Healthcare,Best,NL). Navigator-gated bSSFP cine images (fig.(1)) were used for positioning the spectroscopy voxel (40x20x10mm3) in the interventricular septum and establishing the trigger delay. For B0-shimming an image-based ‘ShimTool’[1,5] was employed. Calibration and PRESS sequences (min.TR=2500ms,TE=41ms,acq.time=512ms) were ECG-triggered to end-systole and navigator-gated, with a large gating-window during acquisitions. To mitigate spectral contamination from outside the VOI, a previously implemented[6] inner-volume-saturation (IVS)[7] scheme was used. For comparison MC PRESS was performed with 256NSA in 4 volunteers and with 512NSA in a fifth volunteer, in whom a 256NSA WS PRESS spectrum was also acquired. The MC FIDs from the 512 NSA acquisition were post-processed in 3 different ways using MRecon(Gyrotools,Zurich,CH): (i) frequency-aligned, phase- and navigator-corrected; (ii)navigator-corrected only; (iii)not corrected. All other acquisitions were fully motion-corrected. Fig.(2) demonstrates the effect of frequency-alignment and phase-correction.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2013-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-013-0382-7
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 30th Annual Scientific Meeting ESMRMB 2013
Veranstaltungsort: Toulouse, France
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 26 (Supplement 1) Artikelnummer: - Start- / Endseite: 62 - 63 Identifikator: -