Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Relaxation of hyperpolarized 129Xe in a deflating polymer bag

Möller, H. E., Cleveland, Z. I., & Driehuys, B. (2011). Relaxation of hyperpolarized 129Xe in a deflating polymer bag. Journal of Magnetic Resonance, 212(1), 109-115. doi:10.1016/j.jmr.2011.06.017.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Möller, Harald E.1, Autor           
Cleveland, Zackary I.2, Autor
Driehuys, Bastiaan2, Autor
Affiliations:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              
2Department of Radiology, Center for In Vivo Microscopy, Center for In Vivo Microscopy, Durham, NC, USA, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Gas-phase relaxation; Hyperpolarized 129Xe; Longitudinal relaxation; Magnetic resonance imaging; Wall relaxation
 Zusammenfassung: In magnetic resonance imaging with hyperpolarized (HP) noble gases, data is often acquired during prolonged gas delivery from a storage reservoir. However, little is known about the extent to which relaxation within the reservoir will limit the useful acquisition time. For quantitative characterization, 129Xe relaxation was studied in a bag made of polyvinyl fluoride (Tedlar). Particular emphasis was on wall relaxation, as this mechanism is expected to dominate. The HP 129Xe magnetization dynamics in the deflating bag were accurately described by a model assuming dissolution of Xe in the polymer matrix and dipolar relaxation with neighboring nuclear spins. In particular, the wall relaxation rate changed linearly with the surface-to-volume ratio and exhibited a relaxivity of κ = 0.392 ± 0.008 cm/h, which is in reasonable agreement with κ = 0.331 ± 0.051 cm/h measured in a static Tedlar bag. Estimates for the bulk gas-phase 129Xe relaxation yielded View the MathML sourceT1bulk=2.55±0.22h, which is dominated by intrinsic Xe–Xe relaxation, with small additional contributions from magnetic field inhomogeneities and oxygen-induced relaxation. Calculations based on these findings indicate that relaxation may limit HP 129Xe experiments when slow gas delivery rates are employed as, for example, in mouse imaging or vascular infusion experiments.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2011-04-202011-06-172011-06-252011-09
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1016/j.jmr.2011.06.017
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: San Diego [etc.] : Academic Press
Seiten: - Band / Heft: 212 (1) Artikelnummer: - Start- / Endseite: 109 - 115 Identifikator: ISSN: 0022-2364
CoNE: https://pure.mpg.de/cone/journals/resource/954922651175_1