Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Strong BOLD-effect with TurboCRAZED MRI following hyperoxia in the rat brain at 16.4 T

Balla, D., Faber, C., Schneider, J., Shajan, G., & Pohmann, R. (2008). Strong BOLD-effect with TurboCRAZED MRI following hyperoxia in the rat brain at 16.4 T. Magnetic Resonance Materials in Physics, Biology and Medicine, 21(Supplement 1): 50, 36-37.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Balla, DZ1, 2, Autor           
Faber, C, Autor
Schneider, JT, Autor
Shajan, G1, 2, Autor           
Pohmann, R1, 2, Autor           
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Introduction: MR imaging techniques based on the indirect detection of intermolecular multiple quantum (iMQC) coherences provide pronounced BOLD signal. The aim of this study was to asses the percent signal change observable via the iMQC BOLD-effect at 16.4T in the rat brain using the accelerated method TurboCRAZED (1).
Subjects and Methods: Experiments were performed on a 16.4T/26cm horizontal bore Magnex magnet interfaced to a Bruker spectrometer. The imaging gradient system had an inner diameter of 12cm. MR images were acquired with homebuilt 14mm and 22mm loop coils. Healthy adult Wistar
rats (255g and 603g) were anesthetized by inhalation of Isoflurane. Breathing was monitored and body temperature was kept constant using electric heating pads.
Results: High resolution TurboCRAZED images were acquired in the rat brain with a nominal inplane resolution of (156μm)2 and a slice thickness of 500μm within one hour measuring time (Fig.1). Experiments with different iMQC correlation length (dc) provided different contrast, because the spatial origin of the local CRAZED signal is in a fair approximation a spherical shell, which can be shifted along the sphere radius by simply changing the
area under the correlation gradient in the pulse sequence. TurboCRAZED images were also sensitive to the BOLD-effect (Fig.2). A 30 minutes time series of four images was acquired, where the animal was inhaling air in the
initial and pure oxygen in the final 15 minutes. The maximum of the difference image was 8.8 from the maximum value in the same brain region of the summed air-images.
Conclusion: High resolution TurboCRAZED images of the rat brain can be obtained in experimental times that allow for fMRI experiments. In combination with the pronounced sensitivity for the BOLD-effect, the tunable iMQC contrast (2) may provide additional information in small animal
fMRI, which is not available with conventional methods.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-09
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-008-0123-5
BibTex Citekey: 5341
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: ESMRMB 2008 Congress: 25th Annual Meeting
Veranstaltungsort: Valencia, Spain
Start-/Enddatum: 2008-10-02 - 2008-10-04

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : No longer published by Elsevier
Seiten: - Band / Heft: 21 (Supplement 1) Artikelnummer: 50 Start- / Endseite: 36 - 37 Identifikator: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532