English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Ratiometric Method for Rapid Monitoring of Biological Processes Using Bioresponsive MRI Contrast Agents

Gündüz, S., Savić, T., Pohmann, R., Logothetis, N., Scheffler, K., & Angelovski, G. (2016). Ratiometric Method for Rapid Monitoring of Biological Processes Using Bioresponsive MRI Contrast Agents. ACS Sensors, 1(5), 483-487. doi:10.1021/acssensors.6b00011.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Gündüz, S1, 2, Author           
Savić, T1, 2, Author           
Pohmann, R1, 3, Author           
Logothetis, NK1, 4, Author           
Scheffler, K1, 3, Author           
Angelovski, G1, 2, Author           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group MR Neuroimaging Agents, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528691              
3Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
4Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

Content

show
hide
Free keywords: -
 Abstract: Bioresponsive MRI contrast agents hold great potential for non-invasive tracking of essential biological processes. Consequently, a number of MR sensors for several imaging protocols have been developed, attempting to produce the maximal signal difference for a given event. Here we introduce an approach which could substantially improve the detection of physiological events with fast kinetics. We developed a nanosized, calcium-sensitive dendrimeric probe that changes longitudinal and transverse relaxation times with different magnitudes. The change in their ratio is rapidly recorded by means of a balanced steady-state free precession (bSSFP) imaging protocol. The employed methodology results in an almost four times greater signal gain per unit of time as compared to conventional T1-weighted imaging with small sized contrast agents. Furthermore, it is suitable for high resolution functional MRI at high magnetic fields. This methodology could evolve into a valuable tool for rapid monitoring of various biological events.

Details

show
hide
Language(s):
 Dates: 2016-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1021/acssensors.6b00011
BibTex Citekey: GunduzSPLSA2016
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: ACS Sensors
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 1 (5) Sequence Number: - Start / End Page: 483 - 487 Identifier: -