English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  On-chip inverted emulsion method for fast giant vesicle production, handling, and analysis

Yandrapalli, N., Seemann, T., & Robinson, T. (2020). On-chip inverted emulsion method for fast giant vesicle production, handling, and analysis. Micromachines, 11(3): 285. doi:10.3390/mi11030285.

Item is

Files

show Files
hide Files
:
Article.pdf (Publisher version), 3MB
Name:
Article.pdf
Description:
-
OA-Status:
Gold
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Yandrapalli, Naresh1, Author           
Seemann, Tina2, Author           
Robinson, Tom1, Author           
Affiliations:
1Tom Robinson, Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_2288691              
2Theorie & Bio-Systeme, Max Planck Institute of Colloids and Interfaces, Max Planck Society, ou_1863289              

Content

show
hide
Free keywords: lab-on-chip; inverted emulsion method; microfluidics; giant vesicles; giant unilamellar vesicles (GUVs); bottom-up synthetic biology
 Abstract: Liposomes and giant unilamellar vesicles (GUVs) in particular are excellent compartments for constructing artificial cells. Traditionally, their use requires bench-top vesicle growth, followed by experimentation under a microscope. Such steps are time-consuming and can lead to loss of vesicles when they are transferred to an observation chamber. To overcome these issues, we present an integrated microfluidic chip which combines GUV formation, trapping, and multiple separate experiments in the same device. First, we optimized the buffer conditions to maximize both the yield and the subsequent trapping of the vesicles in micro-posts. Captured GUVs were monodisperse with specific size of 18 ± 4 µm in diameter. Next, we introduce a two-layer design with integrated valves which allows fast solution exchange in less than 20 s and on separate sub-populations of the trapped vesicles. We demonstrate that multiple experiments can be performed in a single chip with both membrane transport and permeabilization assays. In conclusion, we have developed a versatile all-in-one microfluidic chip with capabilities to produce and perform multiple experiments on a single batch of vesicles using low sample volumes. We expect this device will be highly advantageous for bottom-up synthetic biology where rapid encapsulation and visualization is required for enzymatic reactions.

Details

show
hide
Language(s): eng - English
 Dates: 2020-03-102020
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.3390/mi11030285
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Micromachines
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Basel : MDPI
Pages: - Volume / Issue: 11 (3) Sequence Number: 285 Start / End Page: - Identifier: ISSN: 2072-666X