日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Microwave injection for the ALPHATRAP experiment and developments of the multi-reflection time-of-flight technique of the ISOLTRAP experiment

Steinsberger, T. (2018). Microwave injection for the ALPHATRAP experiment and developments of the multi-reflection time-of-flight technique of the ISOLTRAP experiment. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-AA20-B 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-AA29-2
資料種別: 学位論文

ファイル

表示: ファイル
非表示: ファイル
:
master_thesis_Timo_Steinsberger.pdf (出版社版), 35MB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-0001-AA22-9
ファイル名:
master_thesis_Timo_Steinsberger.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Steinsberger, Timo1, 著者           
所属:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

内容説明

表示:
非表示:
キーワード: -
 MPINP: Präzisionsexperimente - Abteilung Blaum
 要旨: This thesis presents work done at the ALPHATRAP g-factor experiment at the MPIK in Heidelberg and at the mass spectrometry experiment ISOLTRAP at ISOLDE/CERN. At ALPHATRAP a system for microwave transmission from the room temperature environment to the cryogenic trap tower was designed. Microwave horns were used for contact free power transfer in a rst step to a 77K temperature shield and in a second step to the trap tower cooled to 4:2 K. Additional devices for the alignment of a laser beam with the microwaves and a mode lter were designed. At ISOLTRAP, studies for multi-refl ection time-of- flight mass measurements (MR-ToF MS) were performed. A distortion of the peaks in the time-of- ight spectrum due to the radiofrequency eld in the RFQ used for beam preparation was investigated and reduced. In order to improve the ion optics, a new Einzel lens was designed and a new quadrupole bender was commissioned. The stability of mass measurements using the ISOLTRAP MR-ToF MS with ions from an o-line reference ion source were investigated. For measurements with a total recording time of more than one minute, a systematic error on the order of 100 keV was determined. It was reduced for shorter measurement cycles, where the uncertainty due to low statistics dominates.

資料詳細

表示:
非表示:
言語:
 日付: 2018
 出版の状態: 受理 / 印刷中
 ページ: VI, 93 S. : Ill., graph. Darst.
 出版情報: Heidelberg : Ruprecht-Karls-Universität
 目次: -
 査読: -
 識別子(DOI, ISBNなど): -
 学位: 修士号 (Master)

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物

表示: