Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Monitoring triplet state dynamics with fluorescence correlation spectroscopy: Bias and correction.

Schönle, A., von Middendorff, C., Ringemann, C., Hell, S. W., & Eggeling, C. (2014). Monitoring triplet state dynamics with fluorescence correlation spectroscopy: Bias and correction. Microscopy Research and Technique, 77(7), 528-536. doi:10.1002/jemt.22368.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2039313.pdf (Verlagsversion), 281KB
 
Datei-Permalink:
-
Name:
2039313.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Schönle, A.1, Autor           
von Middendorff, C.1, Autor           
Ringemann, C.1, Autor           
Hell, S. W.1, Autor           
Eggeling, C.1, Autor           
Affiliations:
1Department of NanoBiophotonics, MPI for biophysical chemistry, Max Planck Society, ou_578627              

Inhalt

einblenden:
ausblenden:
Schlagwörter: fluorescence microscopy; fluorescence correlation spectroscopy; triplet; intersystem-crossing; fluorescence saturation
 Zusammenfassung: A marker's dark triplet state is of great importance in fluorescence microscopy: It serves as a means to switch off fluorescent markers and is thus the enabling element for several super-resolution methods. On the other hand, intersystem-crossing to the electronic dark triplet state strongly reduces the fluorescence yield in conventional fluorescence microscopy. The ability to determine the kinetic parameters of transitions into the triplet state is thus of great importance and because fluorescence correlation spectroscopy (FCS) can be applied without disturbing the system under study, it is one of the preferred methods to do so. However, conventional FCS observations of triplet dynamics suffer from bias due to the spatially inhomogeneous irradiance profile of the excitation laser. Herein, we present a novel method to correct this bias and verify it by analyzing both Monte Carlo simulated and experimental data of the organic dye Rhodamine 110 in aqueous solution for both continuous-wave and pulsed excitation. Importantly, our approach can be readily generalized to most other FCS experiments that determine intensity dependent kinetic parameters.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014-04-112014-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/jemt.22368
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Microscopy Research and Technique
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 77 (7) Artikelnummer: - Start- / Endseite: 528 - 536 Identifikator: -