  Adaptive-illumination STED nanoscopy.

Heine, J., Reuss, M., Harke, B., D'Este, E., Sahl, S. J., & Hell, S. W. (2017). Adaptive-illumination STED nanoscopy. Proceedings of the National Academy of Sciences of the United States of America, 114(37), 9797-9802. doi:10.1073/pnas.1708304114.

Item is

Files

show Files
hide Files
:
2477079.pdf (Publisher version), 2MB
Name:
2477079.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
2477079_Suppl.DCSupplemental (Supplementary material), 42KB
Name:
2477079_Suppl.DCSupplemental
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/xhtml+xml / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Heine, J., Author
Reuss, M., Author
Harke, B., Author
D'Este, E.1, Author           
Sahl, S. J.2, Author           
Hell, S. W.1, Author           
Affiliations:
1Department of NanoBiophotonics, MPI for Biophysical Chemistry, Max Planck Society, ou_578627              
2Department of NanoBiophotonics, MPI for biophysical chemistry, Max Planck Society, ou_578627              

Content

show
hide
Free keywords: STED microscopy; adaptive illumination; fluorescence nanoscopy; photobleaching; superresolution
 Abstract: The concepts called STED/RESOLFT superresolve features by a light-driven transfer of closely packed molecules between two different states, typically a nonfluorescent "off" state and a fluorescent "on" state at well-defined coordinates on subdiffraction scales. For this, the applied light intensity must be sufficient to guarantee the state difference for molecules spaced at the resolution sought. Relatively high intensities have therefore been applied throughout the imaging to obtain the highest resolutions. At regions where features are far enough apart that molecules could be separated with lower intensity, the excess intensity just adds to photobleaching. Here, we introduce DyMIN (standing for Dynamic Intensity Minimum) scanning, generalizing and expanding on earlier concepts of RESCue and MINFIELD to reduce sample exposure. The principle of DyMIN is that it only uses as much on/off-switching light as needed to image at the desired resolution. Fluorescence can be recorded at those positions where fluorophores are found within a subresolution neighborhood. By tuning the intensity (and thus resolution) during the acquisition of each pixel/voxel, we match the size of this neighborhood to the structures being imaged. DyMIN is shown to lower the dose of STED light on the scanned region up to ∼20-fold under common biological imaging conditions, and >100-fold for sparser 2D and 3D samples. The bleaching reduction can be converted into accordingly brighter images at <30-nm resolution.

Details

show
hide
Language(s): eng - English
 Dates: 2017-08-28
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1073/pnas.1708304114
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Proceedings of the National Academy of Sciences of the United States of America
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 114 (37) Sequence Number: - Start / End Page: 9797 - 9802 Identifier: -