English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Body coil reference for inverse reconstructions of multi-coil data-the case for real-time MRI.

Voit, D., Kalentev, O., & Frahm, J. (2019). Body coil reference for inverse reconstructions of multi-coil data-the case for real-time MRI. Quantitative Imaging in Medicine and Surgery, 9(11), 1815-1819. doi:10.21037/qims.2019.08.14.

Item is

Files

show Files
hide Files
:
3180687.pdf (Publisher version), 3MB
 
File Permalink:
-
Name:
3180687.pdf
Description:
-
OA-Status:
Visibility:
Restricted ( Max Planck Society (every institute); )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Voit, D.1, Author           
Kalentev, O.1, Author           
Frahm, J.1, Author           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Content

show
hide
Free keywords: Black hole; iterative optimization; nonlinear inverse reconstruction; phase singularity; real-time magnetic resonance imaging (real-time MRI)
 Abstract: Real-time magnetic resonance imaging (MRI) or model-based MRI reconstructions of parametric maps require the solution of an ill-posed nonlinear inverse problem. Respective algorithms, e.g., the iteratively regularized Gauss-Newton method, implicitly combine datasets from multiple receive coils. Because these local coils may exhibit complex sensitivity profiles with rather different phase offsets, the numerical optimization may lead to phase singularities which in turn cause "black holes" in magnitude images. The purpose of this work is to develop a method for inverse reconstructions of multi-coil MRI data which avoids the generation of such spatially selective phase singularities. It is proposed to use volumetric body coil data and start the iterative reconstruction of multi-coil data with a reference image which offers proper phase information. In more detail, inverse reconstructions of multi-coil data are initialized with a complex "seed" image which is obtained by a Fast Fourier Transform (FFT) reconstruction of data from a single body coil element. This is accomplished at no additional cost as only very few body coil scans with identical conditions as the multi-coil acquisitions are needed as part of the regular prep scan period. The method is evaluated for anatomical real-time MRI and model-based phase-contrast flow MRI in real-time at 3 T. The proposed method overcomes phase singularities in all cases for arbitrary sets of receive coils. In conclusion, the automatic use of a single body coil reference image is simple, robust, and further improves the reliability of advanced MRI reconstructions from multi-coil data.

Details

show
hide
Language(s): eng - English
 Dates: 2019-11
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.21037/qims.2019.08.14
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Quantitative Imaging in Medicine and Surgery
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 9 (11) Sequence Number: - Start / End Page: 1815 - 1819 Identifier: -