Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Saturated patterned excitation microscopy with two-dimensional excitation patterns

Heintzmann, R. (2003). Saturated patterned excitation microscopy with two-dimensional excitation patterns. Micron, 34, 283-291. Retrieved from http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B6T9N-48XS043-1-30&_cdi=5119&_user=38661&_pii=S0968432803000532&_orig=search&_coverDate=10%2F31%2F2003&_sk=999659993&view=c&wchp=dGLzVlb-zSkzS&md5=75eb5c5b740a4336002576001c27d8a5&ie=/sdarticle.pdf.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
42766.pdf (Verlagsversion), 0B
 
Datei-Permalink:
-
Name:
42766.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Heintzmann, R.1, Autor           
Affiliations:
1Department of Molecular Biology, MPI for biophysical chemistry, Max Planck Society, ou_578628              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Structured Illumination, Non-linear Microscopy, Resolution Enhancement, Widefield, Virtual Microscopy
 Zusammenfassung: The techniques of patterned excitation microscopy (PEM, also referred to in the literature as structured illumination, harmonic excitation light microscopy, or laterally modulated excitation microscopy), has recently been extended to the non-linear regime, permitting a further increase in resolution breaking the Abbé diffraction limit (saturated PEM, SPEM). Fluorescence saturation was suggested as the non-linear effect employed to achieve this aim. Here a two-dimensional extension of the linear and the non-linear patterned excitation technique is introduced and simulations of the expected resolution improvement are presented. The simulations account for photon statistics, a sub-optimal degree of modulation and a high amount of background fluorescence in the sample. The resulting point-spread-functions achieve a full width at half maximum of 215 nm (widefield), 118 nm (linear PEM), and 57 nm (saturated PEM, 9 x 9 orders). For higher resolution, an increased number of detected photons and of raw data images are required. A potential method for substantially decreasing the required number of raw images in PEM and SPEM is discussed.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2003
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Micron
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 34 Artikelnummer: - Start- / Endseite: 283 - 291 Identifikator: -