  CEST imaging at 9.4 T using adjusted adiabatic spin‐lock pulses for on‐ and off‐resonant T1⍴‐dominated Z‐spectrum acquisition

Herz, K., Gandhi, C., Schuppert, M., Deshmane, A., Scheffler, K., & Zaiss, M. (2019). CEST imaging at 9.4 T using adjusted adiabatic spin‐lock pulses for on‐ and off‐resonant T1⍴‐dominated Z‐spectrum acquisition. Magnetic Resonance in Medicine, 81(1), 275-290. doi:10.1002/mrm.27380.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Herz, K1, 2, Author           
Gandhi, C1, 2, Author           
Schuppert, M1, 2, Author           
Deshmane, A1, 2, Author           
Scheffler, K1, 2, Author           
Zaiss, M1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose
The CEST experiment, with its correlation to rare proton species that are in exchange with the water pool, is very similar to the off‐resonant water spin‐lock (SL) experiment. In particular, low‐power SL Z‐spectrum acquisition allows insight into T1ρ and exchange effects with decreased direct water saturation. Because the available SL methods either require high B1 power or are instable in the presence of strong B1 and B0 inhomogeneity present at ultra‐high fields, the goal of this study was to find a robust adiabatic SL pulse for on‐ and off‐resonant application in the human brain at 9.4 T.
Methods
A series of Bloch simulations were used to find optimal pulse shape parameters of an adjusted hyperbolic secant pulse applicable in the low power regime typically used for exchange‐weighted SL experiments. The optimized pulse was implemented and tested in phantom and in vivo experiments on a 9.4 T human scanner for on‐ and off‐resonant T1ρ‐ and Z‐spectrum measurements.
Results
The simulation yielded a feasible pulse shape, which yielded robust images, less sensitivity to B1 and B0 inhomogeneity compared with previous SL approaches and less direct water saturation, as well as a higher chemical exchange weighting compared with conventional CEST approaches.
Conclusion
By adapting a pulse shape for low‐power SL experiments, we were able to acquire robust on‐ and off‐resonant adiabatic SL prepared images in vivo at 9.4 T. This development leads directly to SL Z‐spectrum acquisition, beneficial for chemical‐exchange‐weighted MRI.

Details

show
hide
Language(s):
 Dates: 2018-092019-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.27380
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 81 (1) Sequence Number: - Start / End Page: 275 - 290 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149