Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  GLINT: GlucoCEST in neoplastic tumours at 3T - first-in-man studies of GlucoCEST in glioma patients

Lindig, T., Zaiss, M., Herz, K., Deshmane, A., Bender, B., Golay, X., et al. (2019). GLINT: GlucoCEST in neoplastic tumours at 3T - first-in-man studies of GlucoCEST in glioma patients. Insights into Imaging, 10(Supplement 1): B-0095, S206.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Meeting Abstract

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Lindig, T, Autor           
Zaiss, M1, 2, Autor           
Herz, K1, 2, Autor           
Deshmane, A1, 2, Autor           
Bender, B, Autor           
Golay, X, Autor
Scheffler, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose: Dynamic glucose enhanced (DGE) CEST imaging has almost only
been shown at ultra-high field (UHF) due to low effect size. First results in brain
tumour patients of a DGE CEST method with fast 3D imaging developed for
clinical field strength are shown herein.
Methods and Materials: CEST saturated images at different frequency offsets
were acquired at 160 time points before, during and after a glucose injection
(0.3 mg/kg) with 6.3s temporal resolution (Total: 16:45 min) to detect
accumulation in the brain. Two glioblastoma (IDH wild-type, unmethylated
MGMT promoter) patients (1: male, 70y, 2: female, 75y) and 3 healthy controls
were scanned at a clinical 3T System. DGE contrast images were analysed by
subtracting each image from a pre-injection baseline image:
ΔDGE(t)=DGEbaseline - DGE(t).
Results: In the high-grade glioma (1), glucose uptake in the Gadolinium
enhancing region could be detected approximately 4 minutes after injection
with a maximum increase of ΔDGE=0.51±0.078, whereas a contralateral white
matter ROI was barely affected (ΔDGE=0.07±0.085) at the same time point.
The second glioma (2), with the same histology and grading, showed very little
gadolinium enhancement as well as no significant detectable DGE effect.
Healthy controls did not show any significant DGE contrast.
Conclusion: We demonstrated that stable dynamic glucose enhanced imaging
can be accomplished at clinical field strength using optimized saturation and
readout parameters. First results are promising, and indicate that glucoCEST
corresponds more to the disruptions of the blood-brain-barrier with Gadolinium
uptake than to the molecular tumour profile or tumour grading.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2019-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1186/s13244-019-0713-y
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 25th European Congress of Radiology (ECR 2019): The Bigger Picture
Veranstaltungsort: Wien, Austria
Start-/Enddatum: 2019-02-27 - 2019-03-04

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Insights into Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 10 (Supplement 1) Artikelnummer: B-0095 Start- / Endseite: S206 Identifikator: ISSN: 1869-4101