Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Patient-specific RF safety assessment in MRI: Progress in creating surface-based human head and shoulder models

Kozlov, M., Kalloch, B., Horner, M., Bazin, P.-L., Weiskopf, N., & Möller, H. E. (2019). Patient-specific RF safety assessment in MRI: Progress in creating surface-based human head and shoulder models. In Brain and human body modeling: Computational human modeling at EMBC 2018 (pp. 245-282). Cham: Springer. doi:10.1007/978-3-030-21293-3_13.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Kozlov_2019.pdf (Verlagsversion), 3MB
Name:
Kozlov_2019.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Kozlov, Mikhail1, Autor           
Kalloch, Benjamin2, 3, Autor           
Horner, Marc4, Autor
Bazin, Pierre-Louis1, 2, 5, Autor           
Weiskopf, Nikolaus1, Autor           
Möller, Harald E.6, Autor           
Affiliations:
1Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              
2Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              
3Leipzig University of Applied Sciences, Germany, ou_persistent22              
4ANSYS, Inc., Evanston, IL, ou_persistent22              
5University of Amsterdam, the Netherlands, ou_persistent22              
6Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Biomedical imaging; Computational electromagnetics; Antenna arrays; RF safety
 Zusammenfassung: The interaction of electromagnetic (EM) fields with the human body during magnetic resonance imaging (MRI) is complex and subject specific. MRI radiofrequency (RF) coil performance and safety assessment typically includes numerical EM simulations with a set of human body models. The dimensions of mesh elements used for discretization of the EM simulation domain must be adequate for correct representation of the MRI coil elements, different types of human tissue, and wires and electrodes of additional devices. Examples of such devices include those used during electroencephalography, transcranial magnetic stimulation, and transcranial direct current stimulation, which record complementary information or manipulate brain states during MRI measurement. The electrical contact within and between tissues, as well as between an electrode and the skin, must also be preserved. These requirements can be fulfilled with anatomically correct surface-based human models and EM solvers based on unstructured meshes. Here, we report (i) our workflow used to generate the surface meshes of a head and torso model from the segmented AustinMan dataset, (ii) head and torso model mesh optimization for three-dimensional EM simulation in ANSYS HFSS, and (iii) several case studies of MRI RF coil performance and safety assessment.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2019-08-29
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/978-3-030-21293-3_13
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Brain and human body modeling: Computational human modeling at EMBC 2018
Genre der Quelle: Buch
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Cham : Springer
Seiten: XI, 402 pp. Band / Heft: - Artikelnummer: - Start- / Endseite: 245 - 282 Identifikator: DOI: 10.1007/978-3-030-21293-3
ISBN: 978-3-030-21292-6