English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Spread‐spectrum magnetic resonance imaging

Scheffler, K., Loktyushin, A., Bause, J., Aghaeifar, A., Steffen, T., & Schölkopf, B. (2019). Spread‐spectrum magnetic resonance imaging. Magnetic Resonance in Medicine, 82(3), 877-885. doi:10.1002/mrm.27766.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Scheffler, K1, 2, Author           
Loktyushin, A1, 2, 3, Author           
Bause, J1, 2, Author           
Aghaeifar, A1, 2, Author           
Steffen, T1, 2, Author           
Schölkopf, B3, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Dept. Empirical Inference, Max Planck Institute for Intelligent Systems, Max Planck Society, ou_1497647              

Content

show
hide
Free keywords: -
 Abstract: Purpose
A novel method for the acceleration of MRI acquisition is proposed that relies on the local modulation of magnetic fields. These local modulations provide additional spatial information for image reconstruction that is used to accelerate image acquisition.
Methods
In experiments and simulations, eight local coils connected to current amplifiers were used for rapid local magnetic field variation. Acquired and simulated data were reconstructed to quantify reconstruction errors as a function of the acceleration factor and applied modulation frequency and strength.
Results
Experimental results demonstrate a possible acceleration factor of 2 to 4. Simulations demonstrate the challenges and limits of this method in terms of required magnetic field modulation strengths and frequencies. A normalized mean squared error of below 10% can be achieved for acceleration factors of up to 8 using modulation field strengths comparable to the readout gradient strength at modulation frequencies in the range of 5 to 20 kHz.
Conclusion
Spread‐spectrum MRI represents a new approach to accelerate image acquisition, and it can be independently combined with traditional parallel imaging techniques based on local receive coil sensitivities.

Details

show
hide
Language(s):
 Dates: 2019-042019-09
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.27766
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 82 (3) Sequence Number: - Start / End Page: 877 - 885 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149