  New Design of Electrostatic Mirror Actuators for Application in High-Precision Interferometry

Wittel, H., Hild, S., Bergmann, G., Danzmann, K., & Strain, K. A. (2015). New Design of Electrostatic Mirror Actuators for Application in High-Precision Interferometry. Classical and quantum gravity, 32(17): 175021. doi:10.1088/0264-9381/32/17/175021.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1411.3853.pdf (Preprint), 4MB
Name:
1411.3853.pdf
Beschreibung:
File downloaded from arXiv at 2015-10-15 10:24
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
:
document(4).pdf (beliebiger Volltext), 2MB
Name:
document(4).pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Wittel, H.1, Autor           
Hild, S.1, Autor           
Bergmann, G.1, Autor           
Danzmann, K.1, Autor           
Strain, K. A.1, Autor           
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Physics, Optics, physics.optics, Astrophysics, Instrumentation and Methods for Astrophysics, astro-ph.IM, Physics, Instrumentation and Detectors, physics.ins-det
 Zusammenfassung: We describe a new geometry for electrostatic actuators to be used in sensitive laser interferometers. The arrangement consists of two plates at the sides of the mirror (test mass), and therefore does not reduce its clear aperture as a conventional electrostatic drive (ESD) would do. Using the sample case of the AEI-10m prototype interferometer, we investigate the actuation range and influences of relative misalignment of the ESD plates in respect to the test mass. We find that in the case of the AEI-10 m prototype interferometer, this new kind of ESD could provide a range of 0.28 micrometer when operated at a voltage of 1 kV. In addition, the geometry presented is shown to provide a reduction factor of about 100 in the magnitude of actuator motion coupling to test mass displacement. We show that therefore in the specific case of the AEI-10m interferometer it is possible to mount the ESD actuators directly on the optical table, without spoiling the seismic isolation performance of the triple stage suspension of the main test masses.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2014-11-142015
 Publikationsstatus: Erschienen
 Seiten: 10 pages, 9 figures
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Classical and quantum gravity
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Bristol, U.K. : Institute of Physics
Seiten: - Band / Heft: 32 (17) Artikelnummer: 175021 Start- / Endseite: - Identifikator: ISSN: 0264-9381
CoNE: https://pure.mpg.de/cone/journals/resource/954925513480_1