  Charge measurement and mitigation for the main test masses of the GEO 600 gravitational wave observatory

Hewitson, M., Danzmann, K., Grote, H., Hild, S., Hough, J., Lück, H., et al. (2007). Charge measurement and mitigation for the main test masses of the GEO 600 gravitational wave observatory. Classical and Quantum Gravity, 24(24), 6379-6391. doi:10.1088/0264-9381/24/24/013.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
cqg7_24_013.pdf (Verlagsversion), 676KB
Name:
cqg7_24_013.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
eDoc_access: PUBLIC
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hewitson, Martin1, Autor           
Danzmann, Karsten2, Autor           
Grote, Hartmut2, Autor           
Hild, Stefan2, Autor           
Hough, J., Autor
Lück, Harald2, Autor           
Rowan, S., Autor
Smith, J. R.1, 2, 3, Autor
Strain, Ken A.2, Autor           
Willke, Benno2, Autor           
Affiliations:
1Observational Relativity and Cosmology, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24011              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
3AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24009              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Spurious charging of the test masses in gravitational wave interferometers is a well-known problem. Typically, concern arises due to the possibility of increased thermal noise due to a lowering of the quality factor of modes of the test-mass suspension, or due to the potential for increased displacement noise arising from charge migration on the surface of the test masses. Recent experience gained at the GEO 600 gravitational wave detector has highlighted an additional problem. GEO 600 uses electrostatic actuators to control the longitudinal position of the main test masses. The presence of charge on the test masses is shown to strongly affect the performance of the electrostatic actuators. This paper reports on a measurement scheme whereby the charge state of the GEO 600 test masses can be measured using the electrostatic actuators. The resulting measurements are expressed in terms of an effective bias voltage on the electrostatic actuators. We also describe attempts to remove the charge from the test masses and we show that the use of UV illumination was the most successful. Using UV illumination we were able to discharge and re-charge the test masses.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2007-12-21
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 334866
ISI: 000251428600014
DOI: 10.1088/0264-9381/24/24/013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Classical and Quantum Gravity
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 24 (24) Artikelnummer: - Start- / Endseite: 6379 - 6391 Identifikator: ISSN: 0264-9381