日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  A comparison of optimization algorithms for localized in vivo B0 shimming

Nassirpour, S., Chang, P., Fillmer, A., & Henning, A. (2018). A comparison of optimization algorithms for localized in vivo B0 shimming. Magnetic Resonance in Medicine, 79(2), 1145-1156. doi:10.1002/mrm.26758.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-7CFA-B 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-8044-1
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Nassirpour, S1, 2, 著者           
Chang, P1, 2, 著者           
Fillmer, A, 著者
Henning, A1, 2, 著者           
所属:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              

内容説明

表示:
非表示:
キーワード: -
 要旨: PURPOSE: To compare several different optimization algorithms currently used for localized in vivo B0 shimming, and to introduce a novel, fast, and robust constrained regularized algorithm (ConsTru) for this purpose. METHODS: Ten different optimization algorithms (including samples from both generic and dedicated least-squares solvers, and a novel constrained regularized inversion method) were implemented and compared for shimming in five different shimming volumes on 66 in vivo data sets from both 7 T and 9.4 T. The best algorithm was chosen to perform single-voxel spectroscopy at 9.4 T in the frontal cortex of the brain on 10 volunteers. RESULTS: The results of the performance tests proved that the shimming algorithm is prone to unstable solutions if it depends on the value of a starting point, and is not regularized to handle ill-conditioned problems. The ConsTru algorithm proved to be the most robust, fast, and efficient algorithm among all of the chosen algorithms. It enabled acquisition of spectra of reproducible high quality in the frontal cortex at 9.4 T. CONCLUSIONS: For localized in vivo B0 shimming, the use of a dedicated linear least-squares solver instead of a generic nonlinear one is highly recommended. Among all of the linear solvers, the constrained regularized method (ConsTru) was found to be both fast and most robust.

資料詳細

表示:
非表示:
言語:
 日付: 2018-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.26758
BibTex参照ID: NassirpourCFH2017
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 79 (2) 通巻号: - 開始・終了ページ: 1145 - 1156 識別子(ISBN, ISSN, DOIなど): -