  Constrained optimization for position calibration of an NMR field camera

Chang, P., Nassirpour, S., Eschelbach, M., Scheffler, K., & Henning, A. (2018). Constrained optimization for position calibration of an NMR field camera. Magnetic Resonance Imaging, 80(1), 380-390. doi:10.1002/mrm.27010.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Chang, P1, 2, Author           
Nassirpour, S1, 2, Author           
Eschelbach, M2, 3, Author           
Scheffler, K2, 3, Author           
Henning, A1, 2, Author           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose: Knowledge of the positions of field probes in an NMR field camera is necessary for monitoring the B0 field. The typical method of estimating these positions is by switching the gradients with known strengths and calculating the positions using the phases of the FIDs. We investigated improving the accuracy of estimating the probe positions and analyzed the effect of inaccurate estimations on field monitoring. Methods: The field probe positions were estimated by 1) assuming ideal gradient fields, 2) using measured gradient fields (including nonlinearities), and 3) using measured gradient fields with relative position constraints. The fields measured with the NMR field camera were compared to fields acquired using a dual-echo gradient recalled echo B0 mapping sequence. Comparisons were done for shim fields from second- to fourth-order shim terms. Results: The position estimation was the most accurate when relative position constraints were used in conjunction with measured (nonlinear) gradient fields. The effect of more accurate position estimates was seen when compared to fields measured using a B0 mapping sequence (up to 10–15 more accurate for some shim fields). The models acquired from the field camera are sensitive to noise due to the low number of spatial sample points. Conclusion Position estimation of field probes in an NMR camera can be improved using relative position constraints and nonlinear gradient fields.

Details

show
hide
Language(s):
 Dates: 2017-112018-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.27010
BibTex Citekey: ChangNESH2017
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Imaging
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 80 (1) Sequence Number: - Start / End Page: 380 - 390 Identifier: -