Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Thermal vacuum and balance test of the ESA Solar Orbiter Instrument PHI

Fernandez-Rico, G., Alvarez-Copano, M., Deutsch, W., Gandorfer, A. M., Ramanath, S., Staub, J., et al. (2018). Thermal vacuum and balance test of the ESA Solar Orbiter Instrument PHI. In International Conference on Environmental Systems.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Konferenzbeitrag

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Fernandez-Rico, German1, 2, Autor
Alvarez-Copano, Miguel, Autor
Deutsch, Werner1, Autor           
Gandorfer, Achim M.1, Autor           
Ramanath, Sandeep, Autor
Staub, Jan1, Autor           
Bambach, Patrick2, Autor           
Torralbo, Ignacio, Autor
Affiliations:
1Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society, ou_1832289              
2IMPRS for Solar System Science at the University of Göttingen, Max Planck Institute for Solar System Research, Max Planck Society, Justus-von-Liebig-Weg 3, 37077 Göttingen, DE, ou_1832290              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: PHI (Polarimetric and Helioseismic Imager) is one of the remote sensing instruments which will fly on board of ESA Solar Orbiter mission. It consists of two entrance filters, an optics unit, an electronics unit and an external harness that links both units. Prior to the instrument delivery to the Spacecraft prime contractor (Airbus UK), PHI was subjected to a thermal vacuum cycling test, which is described in this paper. The test had a threefold objective: the acceptance test of the optics and electronics unit, the thermal model correlation of the optics unit, and the spectral calibration of the instrument. The PHI optics unit is an internally mounted insulated unit, thermally coupled to the spacecraft only through dedicated interfaces and optical apertures towards the Sun, whereas the electronics unit is strongly coupled to the spacecraft through its base. These characteristics required the control of up to 12 interfaces, including the thermal vacuum chamber shroud. For the spectral calibration, it was needed to feed the instrument with natural sunlight. This was done by means of a coelostat that drives the sunlight through the building inside the thermal vacuum chamber. Due to geometrical distribution of baseplate and viewports in the chamber, it was necessary to mount the whole PHI instrument on a high stand 0.5 m above the thermal vacuum chamber baseplate, which was used as a general heat sink for the controlled interfaces. Finally, the entrance filters were monitored through infrared cameras, which could see inside the chamber through dedicated Zinc-Selenide viewports and a mobile stainless steel flat mirror.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2018
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Keine Begutachtung
 Identifikatoren: Anderer: http://hdl.handle.net/2346/74235
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: International Conference on Environmental Systems
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: - Start- / Endseite: - Identifikator: -