日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM

Glaeser, R. M., Sassolini, S., Cambie, R., Jin, J., Cabrini, S., Schmid, A. K., Danev, R., Buijsse, B., Csencsits, R., Downing, K. H., Larson, D. M., Typke, D., & Han, B. G. (2013). Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM. ULTRAMICROSCOPY, 135, 6-15. doi:10.1016/j.ultramic.2013.05.023.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Glaeser, Robert M.1, 著者
Sassolini, Simone1, 著者
Cambie, Rossana1, 著者
Jin, Jian1, 著者
Cabrini, Stefano1, 著者
Schmid, Andreas K.1, 著者
Danev, Radostin2, 著者           
Buijsse, Bart1, 著者
Csencsits, Roseann1, 著者
Downing, Kenneth H.1, 著者
Larson, David M.1, 著者
Typke, Dieter1, 著者
Han, B. G.1, 著者
所属:
1external, ou_persistent22              
2Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565142              

内容説明

表示:
非表示:
キーワード: IRRADIATED GRAPHITE; ENERGY-RELEASE; CRYO-EM; MICROSCOPY; PLATES; STREPTAVIDIN; IMAGE; SPECIMEN; CRYSTALS; DESIGNPhase contrast; Charging; Cryo-EM; Phase plate;
 要旨: Microfabricated devices designed to provide phase contrast in the transmission electron microscope must be free of phase distortions caused by unexpected electrostatic effects. We find that such phase distortions occur even when a device is heated to 300 degrees C during use in order to avoid the formation of polymerized, carbonaceous contamination. Remaining factors that could cause unwanted phase distortions include patchy variations in the work function of a clean metal surface, radiation-induced formation of a localized oxide layer, and creation of a contact potential between an irradiated area and the surround due to radiation-induced structural changes. We show that coating a microfabricated device with evaporated carbon apparently eliminates the problem of patchy variation in the work function. Furthermore, we show that a carbon-coated titanium device is superior to a carbon-coated gold device, with respect to radiation-induced electrostatic effects. A carbon-coated, hybrid double-sideband/single-sideband aperture is used to record in-focus, cryo-EM images of monolayer crystals of streptavidin. Images showing no systematic phase error due to charging are achievable under conditions of lowdose data collection. The contrast in such in-focus images is sufficient that one can readily see individual streptavidin tetramer molecules. Nevertheless, these carbon-coated devices perform well for only a limited length of time, and the cause of failure is not yet understood. (C) 2013 Elsevier B.V. All rights reserved.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2013-12
 出版の状態: 出版
 ページ: 10
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): ISI: 000326941500002
DOI: 10.1016/j.ultramic.2013.05.023
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: ULTRAMICROSCOPY
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS : ELSEVIER SCIENCE BV
ページ: - 巻号: 135 通巻号: - 開始・終了ページ: 6 - 15 識別子(ISBN, ISSN, DOIなど): ISSN: 0304-3991