  Using carbogen for calibrated fMRI at 7 Tesla: Comparison of direct and modelled estimation of the M parameter

Krieger, S., Ivanov, D., Huber, L., Roggenhofer, E., Sehm, B., Turner, R., et al. (2014). Using carbogen for calibrated fMRI at 7 Tesla: Comparison of direct and modelled estimation of the M parameter. NeuroImage, 84, 605-614. doi:10.1016/j.neuroimage.2013.09.035.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Krieger, Steffen1, 2, Autor           
Ivanov, Dimo1, 3, Autor           
Huber, Laurentius1, Autor           
Roggenhofer, Elisabeth4, Autor           
Sehm, Bernhard4, Autor           
Turner, Robert1, Autor           
Egan, Gary F.2, Autor
Gauthier, Claudine1, Autor           
Affiliations:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
2Monash Biomedical Imaging, Monash University, Melbourne, Australia, ou_persistent22              
3Maastricht Brain Imaging Centre, Maastricht University, the Netherlands, ou_persistent22              
4Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Calibrated fMRI; BOLD; Hypercapnia; Hyperoxia; CMRO2; Metabolism
 Zusammenfassung: Task-evoked changes in cerebral oxygen metabolism can be measured using calibrated functional Magnetic Resonance Imaging (fMRI). This technique requires the use of breathing manipulations such as hypercapnia, hyperoxia or a combination of both to determine a calibration factor M. The M-value is usually obtained by extrapolating the BOLD signal measured during the gas manipulation to its upper theoretical physiological limit using a biophysical model. However, a recently introduced technique uses a combination of increased inspired concentrations of O2 and CO2 to saturate the BOLD signal completely. In this study, we used this BOLD saturation technique to measure M directly at 7 Tesla (T). Simultaneous carbogen-7 (7 % CO2 in 93 % O2) inhalation and visuo-motor
task performance was used to elevate venous oxygen saturation in visual and motor areas close to their maximum, and the BOLD signal measured during this manipulation was used as an estimate of M.
As accurate estimation of M is crucial for estimation of valid oxidative metabolism values, these directly estimated M-values were assessed and compared with M-values obtained via extrapolation modelling using the generalized calibration model (GCM) on the same dataset. Average M-values measured using both methods were 10.4±3.9 % (modelled) and 7.5±2.2 % (direct) for a visual-related ROI, and 11.3±5.2 % (modelled) and 8.1±2.6 % (direct) for a motor-related ROI. Results from this study suggest that, for the CO2 concentration used here, modelling is necessary for the accurate estimation of the M parameter. Neither gas inhalation alone, nor gas inhalation combined with a visuomotor task, was sufficient to completely saturate venous blood in most subjects. Calibrated fMRI studies should therefore rely on existing models for gas inhalation-based calibration of the BOLD
signal.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-09-132013-09-242014-01-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.neuroimage.2013.09.035
PMID: 24071526
Anderer: Epub 2013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: NeuroImage
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 84 Artikelnummer: - Start- / Endseite: 605 - 614 Identifikator: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166