Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Towards ultrahigh-resolution multi-reflection time-of-flight mass spectrometry at ISOLTRAP

Wienholtz, F., Atanasov, D., Kreim, S. W., Manea, V., Rosenbusch, M., Schweikhard, L., et al. (2015). Towards ultrahigh-resolution multi-reflection time-of-flight mass spectrometry at ISOLTRAP. Physica Scripta T, 2015(T166): 014068. doi:10.1088/0031-8949/2015/T166/014068.

Item is

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://dx.doi.org/10.1088/0031-8949/2015/T166/014068 (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Wienholtz, F.1, Autor
Atanasov, Dinko2, Autor           
Kreim, Susanne Waltraud2, 3, Autor           
Manea, Vladimir2, Autor           
Rosenbusch, M.1, Autor
Schweikhard, L.1, Autor
Welker, A.4, Autor
Wolf, Robert2, Autor           
Affiliations:
1Institut für Physik, Ernst-Moritz-Arndt-Universität, 17487 Greifswald, Germany, ou_persistent22              
2Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
3CERN, 1211 Geneva 23, Switzerland, ou_persistent22              
4Technische Universität Dresden, 01069 Dresden, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Proceedings of the 9th International Conference on Nuclear Physics at Storage Rings STORI'14
 MPINP: Speichertechnik - Abteilung Blaum
 Zusammenfassung: The mass resolving power of the multi-reflection time-of-flight mass spectrometer of ISOLTRAP was studied by monitoring 39K+ signals. A drift tube at the center of the MR-ToF MS allows decreasing or increasing the kinetic energy of the ion bunch, by switching its potential when the ions are traversing it. This offers the possibility of capturing and ejecting ion bunches by controlling a single voltage by the so-called in-trap lift technique. It also allows changing the energy of the trapped ions inside the MR-ToF MS, offering a way to optimize the resolving power of the device. For a fixed number of 2000 laps corresponding to a total ion flight time of about 30 ms, data was accumulated for 100 experimental cycles, adding to a duration of 10 s for each spectrum. Without any subsequent corrections for broadening effects, mass resolving powers in excess of 300 000 (FWHM) were obtained.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2015-11-26
 Publikationsstatus: Erschienen
 Seiten: 4
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1088/0031-8949/2015/T166/014068
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physica Scripta T
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Bristol; Stockholm : IOP Publishing; Royal Swedish Academy of Sciences
Seiten: - Band / Heft: 2015 (T166) Artikelnummer: 014068 Start- / Endseite: - Identifikator: ISSN: 0281-1847
CoNE: https://pure.mpg.de/cone/journals/resource/110976549881403