日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Anatomical brain imaging at 7T using two-dimensional GRASE

Trampel, R., Reimer, E., Huber, L., Ivanov, D., Heidemann, R. M., Schäfer, A., & Turner, R. (2014). Anatomical brain imaging at 7T using two-dimensional GRASE. Magnetic Resonance in Medicine, 72(5), 1291-1301. doi:10.1002/mrm.25047.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Trampel, Robert1, 著者           
Reimer, Enrico1, 著者           
Huber, Laurentius1, 2, 著者           
Ivanov, Dimo1, 3, 著者           
Heidemann, Robin M.1, 4, 著者           
Schäfer, Andreas1, 著者           
Turner, Robert1, 著者           
所属:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              
2Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, Leipzig, DE, ou_634558              
3Maastricht University, The Netherlands, ou_persistent22              
4Siemens AG, Erlangen, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: GRASE; structural imaging; brain; high resolution; 7 Tesla; SAR
 要旨: Purpose: Specific absorption rate is a serious problem at high field strengths, especially for sequences involving many high power radiofrequency pulses, such as turbo spin echo (TSE). GRASE (gradient and spin echo) may overcome this problem by omitting a certain number of refocusing pulses of a TSE sequence, and replacing them with segmented echo-planar imaging readouts.
Methods: GRASE and TSE were compared using similar sequence parameters at a field strength of 7T. The signal-to-noise ratio (SNR) per unit time, contrast, and point spread function (PSF) were determined. High-resolution human brain images were acquired and the implementation of an inversion recovery preparation for T1 weighting was evaluated.
Results: TSE and GRASE images at 7T showed very similar SNR and contrast. The slightly worse PSF for GRASE is balanced by a significant reduction in scan time or increase in spatial coverage compared with TSE. Furthermore, implementing an additional inversion recovery preparation enables the acquisition of T1-weighted images with high SNR per unit time.
Conclusion: GRASE is highly suitable for structural scanning at ultra-high field strengths and is a valid alternative to the commonly used TSE sequence.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2013-10-252013-05-292013-10-242013-12-172014-11
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.25047
PMID: 24443053
その他: Epub 2013
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Wiley-Liss
ページ: - 巻号: 72 (5) 通巻号: - 開始・終了ページ: 1291 - 1301 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149