Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Fast and Quantitative T1ρ-weighted Dynamic Glucose Enhanced MRI

Schuenke, P., Paech, D., Koehler, C., Windschuh, J., Bachert, P., Ladd, M., et al. (2017). Fast and Quantitative T1ρ-weighted Dynamic Glucose Enhanced MRI. Scientific Reports, 7: 42093, pp. 1-10. doi:10.1038/srep42093.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Schuenke, P, Autor
Paech, D, Autor
Koehler, C, Autor
Windschuh, J, Autor
Bachert, P, Autor
Ladd, ME, Autor
Schlemmer, H-P, Autor
Radbruch, A, Autor
Zaiss, M1, 2, Autor           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Common medical imaging techniques usually employ contrast agents that are chemically labeled, e.g. with radioisotopes in the case of PET, iodine in the case of CT or paramagnetic metals in the case of MRI to visualize the heterogeneity of the tumor microenvironment. Recently, it was shown that natural unlabeled D-glucose can be used as a nontoxic biodegradable contrast agent in Chemical Exchange sensitive Spin-Lock (CESL) magnetic resonance imaging (MRI) to detect the glucose uptake and potentially the metabolism of tumors. As an important step to fulfill the clinical needs for practicability, reproducibility and imaging speed we present here a robust and quantitative T1ρ-weighted technique for dynamic glucose enhanced MRI (DGE-MRI) with a temporal resolution of less than 7 seconds. Applied to a brain tumor patient, the new technique provided a distinct DGE contrast between tumor and healthy brain tissue and showed the detailed dynamics of the glucose enhancement after intravenous injection. Development of this fast and quantitative DGE-MRI technique allows for a more detailed analysis of DGE correlations in the future and potentially enables non-invasive diagnosis, staging and monitoring of tumor response to therapy.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2017-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1038/srep42093
BibTex Citekey: SchuenkePKWBLSRZ2017
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Scientific Reports
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 7 Artikelnummer: 42093 Start- / Endseite: 1 - 10 Identifikator: -