  Dynamic changes of acoustic load and complex impedance as reporters for the cytotoxicity of small molecule inhibitors

Tarantola, M., Sunnick, E., Schneider, D., Marel, A. K., Kunze, A., & Janshoff, A. (2011). Dynamic changes of acoustic load and complex impedance as reporters for the cytotoxicity of small molecule inhibitors. Chemical Research in Toxicology, 24(9), 1494-506. doi:10.1021/tx200115q.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Tarantola, M.1, Author           
Sunnick, E., Author
Schneider, D., Author
Marel, A. K., Author
Kunze, A., Author
Janshoff, A., Author
Affiliations:
1Laboratory for Fluid Dynamics, Pattern Formation and Biocomplexity, Max Planck Institute for Dynamics and Self-Organization, Max Planck Society, ou_2063287              

Content

show
hide
Free keywords: -
 Abstract: Cellular motility is the major driving force of numerous biological phenomena including wound healing, immune response, embryogenesis, cancer formation, and metastasis. We studied the response of epithelial FaDu monolayers cultured on gold electrodes of an acoustic resonator (quartz crystal microbalance, QCM) and impedance sensor (electric cell-substrate impedance sensing, ECIS) to externally applied chemical stimuli interfering with cytoskeleton organization. Epithelial cell motility of confluent monolayers is characterized by subtle cell shape changes and variations in the cell-substrate as well as cell-cell distance without net directionality of individual cells. The impact of small molecules such as cytochalasin D, phalloidin, and blebbistatin as well as paclitaxel, nocodazol, and colchicin on actin and microtubules organization was quantified by conventional sensors' readouts and by comparing the noise pattern of the signals which is attributed to cellular dynamics. The responsiveness of noninvasive and label-free techniques relying on cellular dynamics is compared to classical viability assays and changes of the overall impedance of ultrasmall electrodes or acoustic loads of a thickness shear mode resonator. Depending on the agent used, a distinct sensor response was found, which can be used as a fingerprint of the cellular response. Cytoskeletal rearrangements and nuclear integrity were corroborated by fluorescence microscopy and correlated to the readouts of QCM and ECIS.

Details

show
hide
Language(s): eng - English
 Dates: 2011-08-042011
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1021/tx200115q
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Chemical Research in Toxicology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 24 (9) Sequence Number: - Start / End Page: 1494 - 506 Identifier: -