Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Theoretical study of preparative chromatography using closed-loop recycling with an initial gradient

Sreedhar, B., Damtew Hamza, A., & Seidel-Morgenstern, A. (2009). Theoretical study of preparative chromatography using closed-loop recycling with an initial gradient. Journal of Chromatography A, 1216(25), 4976-4988. doi:10.1016/j.chroma.2009.04.057.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Sreedhar, B.1, 2, Autor           
Damtew Hamza, Andualem1, 3, Autor           
Seidel-Morgenstern, A.1, 3, Autor           
Affiliations:
1Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
2International Max Planck Research School (IMPRS), Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, DE, ou_1738143              
3Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Preparative chromatography; Closed-loop recycling; Gradient elution; Closed-loop recycling with initial gradient; Parallel grid search; Optimization; Craig model
 Zusammenfassung: Complementing classical isocratic elution, several more sophisticated operating modes have been proposed and are applied in preparative chromatography in order to improve performance. One such approach is gradient elution, where the solvent strength is altered by varying the fraction of a modifier added to the mobile phase to enhance selectivity and to achieve faster elution. Another useful technique is closed-loop recycling, allowing better peak resolution and increased yields. This study focuses on a modified new scheme which incorporates the advantages of both gradient elution and closed-loop recycling for the separation of a ternary mixture where the intermediately eluting component is the target. A parametric study was carried out using typical adsorption isotherm parameters to elucidate the effects of varying loading factors and parameters specific to the two basic operational modes on production rates and yields. A comparison was also made between the proposed scheme and conventional techniques. It was found that the studied scheme could exploit increased column loadings and offers significantly higher production rates. Copyright © 2009 Elsevier B.V. All rights reserved. [accessed July 27, 2009]

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2009
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 433492
DOI: 10.1016/j.chroma.2009.04.057
Anderer: 15/09
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Chromatography A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Elsevier
Seiten: - Band / Heft: 1216 (25) Artikelnummer: - Start- / Endseite: 4976 - 4988 Identifikator: ISSN: 0021-9673