English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Stability of halocarbons in air samples stored in stainless-steel canisters

Schuck, T. J., Blank, A.-K., Rittmeier, E., Williams, J., Brenninkmeijer, C. A. M., Engel, A., et al. (2020). Stability of halocarbons in air samples stored in stainless-steel canisters. Atmospheric Measurement Techniques, 13(1), 73-84. doi:10.5194/amt-13-73-2020.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Schuck, Tanja J.1, Author
Blank, Ann-Katrin1, Author
Rittmeier, Elisa1, Author
Williams, Jonathan2, Author           
Brenninkmeijer, Carl A. M.2, Author           
Engel, Andreas1, Author
Zahn, Andreas1, Author
Affiliations:
1external, ou_persistent22              
2Atmospheric Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826285              

Content

show
hide
Free keywords: -
 Abstract: Measurements of halogenated trace gases in ambient air frequently rely on canister sampling followed by offline laboratory analysis. This allows for a large number of compounds to be analysed under stable conditions, maximizing measurement precision. However, individual compounds might be affected during the sampling and storage of canister samples. In order to assess halocarbon stability in whole-air samples from the upper troposphere and lowermost stratosphere, we performed stability tests using the high-resolution sampler (HIRES) air sampling unit, which is part of the Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container (CARIBIC) instrument package. The HIRES unit holds 88 lightweight stainless-steel cylinders that are pressurized in flight to 4.5 bar using metal bellows pumps. The HIRES unit was first deployed in 2010 but has up to now not been used for regular halocarbon analysis with the exception of chloromethane analysis. The sample collection unit was tested for the sampling and storage effects of 28 halogenated compounds. The focus was on compound stability in the stainless-steel canisters during storage of up to 5 weeks and on the influence of ozone, since flights take place in the upper troposphere and lowermost stratosphere with ozone mixing ratios of up to several hundred parts per billion by volume (ppbv). Most of the investigated (hydro)chlorofluorocarbons and long-lived hydrofluorocarbons were found to be stable over a storage time of up to 5 weeks and were unaltered by ozone being present during pressurization. Some compounds such as dichloromethane, trichloromethane, and tetrachloroethene started to decrease in the canisters after a storage time of more than 2 weeks or exhibited lowered mixing ratios in samples pressurized with ozone present. A few compounds such as tetrachloromethane and tribromomethane were found to be unstable in the HIRES stainless-steel canisters independent of ozone levels. Furthermore, growth was observed during storage for some species, namely for HFC-152a, HFC-23, and Halon 1301.

Details

show
hide
Language(s):
 Dates: 2020
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000506843900001
DOI: 10.5194/amt-13-73-2020
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Atmospheric Measurement Techniques
  Abbreviation : AMT
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Göttingen : European Geosciences Union, Copernicus
Pages: - Volume / Issue: 13 (1) Sequence Number: - Start / End Page: 73 - 84 Identifier: ISSN: 1867-1381
CoNE: https://pure.mpg.de/cone/journals/resource/1867-1381