Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  A synchronized VUV light source based on high-order harmonic generation at FLASH

Appi, E., Papadopoulou, C. C., Mapa, J. L., Wesavkar, N., Jusko, C., Mosel, P., et al. (2020). A synchronized VUV light source based on high-order harmonic generation at FLASH. Scientific Reports, 10: 6867. doi:10.1038/s41598-020-63019-2.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://www.nature.com/articles/s41598-020-63019-2.pdf (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Appi, Elisa, Autor
Papadopoulou, Christina C., Autor
Mapa, Jose Louise, Autor
Wesavkar, Nishad, Autor
Jusko, Christoph, Autor
Mosel, Philip, Autor
Ališauskas, Skirmantas, Autor
Lang, Tino, Autor
Heyl, Christoph M., Autor
Manschwetus, Bastian, Autor
Brachmanski, Maciej, Autor
Braune, Markus, Autor
Lindenblatt, Hannes Carsten1, Autor           
Trost, Florian1, Autor           
Meister, Severin1, Autor           
Schoch, Patrizia1, Autor           
Treusch, Rolf, Autor
Moshammer, Robert1, Autor           
Hartl, Ingmar, Autor
Morgner, Uwe, Autor
Kovacev, Milutin, Autor mehr..
Affiliations:
1Division Prof. Dr. Thomas Pfeifer, MPI for Nuclear Physics, Max Planck Society, ou_2025284              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Ultrafast measurements in the extreme ultraviolet (XUV) spectral region targeting femtosecond timescales rely until today on two complementary XUV laser sources: free electron lasers (FELs) and high-harmonic generation (HHG) based sources. The combination of these two source types was until recently not realized. The complementary properties of both sources including broad bandwidth, high pulse energy, narrowband tunability and femtosecond timing, open new opportunities for two-color pump-probe studies. Here we show first results from the commissioning of a high-harmonic beamline that is fully synchronized with the free-electron laser FLASH, installed at beamline FL26 with permanent end-station including a reaction microscope (REMI). An optical parametric amplifier synchronized with the FEL burst mode drives the HHG process. First commissioning tests including electron momentum measurements using REMI, demonstrate long-term stability of the HHG source over more than 14 hours. This realization of the combination of these light sources will open new opportunities for time-resolved studies targeting different science cases including core-level ionization dynamics or the electron dynamics during the transformation of a molecule within a chemical reaction probed on femtosecond timescales in the ultraviolet to soft X-ray spectral region.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2020-04-22
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1038/s41598-020-63019-2
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Scientific Reports
  Kurztitel : Sci. Rep.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: London, UK : Nature Publishing Group
Seiten: - Band / Heft: 10 Artikelnummer: 6867 Start- / Endseite: - Identifikator: ISSN: 2045-2322
CoNE: https://pure.mpg.de/cone/journals/resource/2045-2322