  Assessment of a clinically feasible Bayesian fitting algorithm using a simplified description of Chemical Exchange Saturation Transfer (CEST) imaging

Kujawa, A., Kim, M., Demetriou, E., Anemone, A., Livio Longo, D., Zaiss, M., et al. (2019). Assessment of a clinically feasible Bayesian fitting algorithm using a simplified description of Chemical Exchange Saturation Transfer (CEST) imaging. Journal of Magnetic Resonance, 300, 120-134. doi:10.1016/j.jmr.2019.01.006.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Kujawa, A, Autor
Kim, M, Autor
Demetriou, E, Autor
Anemone, A, Autor
Livio Longo, D, Autor
Zaiss, M1, 2, Autor           
Golay, X, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Fitting a model based on the Bloch-McConnell (BM) equations to Chemical Exchange Saturation Transfer (CEST) spectra allows for the quantification of metabolite concentration and exchange rate as well as simultaneous correction of field inhomogeneity, direct water saturation and magnetization transfer. Employing a Bayesian fitting approach permits the integration of prior information into the analysis to incorporate expected parameter distributions and to prevent over-fitting. However, the analysis can be time consuming if a general numerical solution of the BM equations is applied. In this study, we combined a Bayesian fitting algorithm with approximate analytical solutions of the BM equations to achieve feasible computational times. To evaluate the accuracy and speed of the suggested approach, phantoms including Iodipamide, Taurine and Creatine were tested in addition to simulated data with continuous-wave (CW) and pulsed saturation with Gaussian pulses. A significant reduction of computational time was achieved when fitting CW data (about 50-fold) and pulsed saturation data (more than 100-fold) with the analytical model while the estimated parameters were largely consistent with the parameters from the general numerical solution. The increased speed of the algorithm facilitates the Bayesian analysis of CEST data within clinically feasible processing times. Other analytical models valid for different parameter regimes may be employed to extend the applicability to a wider range of CEST agents.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2019-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1016/j.jmr.2019.01.006
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: San Diego [etc.] : Academic Press
Seiten: - Band / Heft: 300 Artikelnummer: - Start- / Endseite: 120 - 134 Identifikator: ISSN: 0022-2364