Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  An instrument for measurements of BrO with LED-based Cavity-Enhanced Differential Optical Absorption Spectroscopy

Hoch, D. J., Buxmann, J., Sihler, H., Pöhler, D., Zetzsch, C., & Platt, U. (2014). An instrument for measurements of BrO with LED-based Cavity-Enhanced Differential Optical Absorption Spectroscopy. Atmospheric Measurement Techniques, 7(1), 199-214. doi:10.5194/amt-7-199-2014.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hoch, D. J.1, Autor
Buxmann, J.1, Autor
Sihler, H.2, Autor           
Pöhler, D.1, Autor
Zetzsch, C.1, Autor
Platt, U.1, Autor
Affiliations:
1external, ou_persistent22              
2Satellite Remote Sensing, Max Planck Institute for Chemistry, Max Planck Society, ou_1826293              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The chemistry of the troposphere and specifically the global tropospheric ozone budget is affected by reactive halogen species such as bromine monoxide (BrO) or chlorine monoxide (ClO). Especially BrO plays an important role in the processes of ozone destruction, disturbance of NOx and HOx chemistry, oxidation of dimethyl sulfide (DMS), and the deposition of elementary mercury. In the troposphere BrO has been detected in polar regions, at salt lakes, in volcanic plumes, and in the marine boundary layer. For a better understanding of these processes, field measurements as well as reaction chamber studies are performed. In both cases instruments with high spatial resolution and high sensitivity are necessary. A Cavity-Enhanced Differential Optical Absorption Spectroscopy (CE-DOAS) instrument with an open path measurement cell was designed and applied. For the first time, a CE-DOAS instrument is presented using an UV LED in the 325-365 nm wavelength range. In laboratory studies, BrO as well as HONO, HCHO, O-3, and O-4 could be reliably determined at detection limits of 20 ppt for BrO, 9.1 ppb for HCHO, 970 ppt for HONO, and 91 ppb for O-3, for five minutes integration time. The best detection limits were achieved for BrO (11 ppt), HCHO (5.1 ppb), HONO (490 ppt), and O-3 (59 ppb) for integration times of 81 minutes or less. Comparison with established White system (WS) DOAS and O-3 monitor measurements demonstrate the reliability of the instrument.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2014
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: ISI: 000330945400015
DOI: 10.5194/amt-7-199-2014
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Atmospheric Measurement Techniques
  Kurztitel : AMT
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Göttingen : European Geosciences Union, Copernicus
Seiten: - Band / Heft: 7 (1) Artikelnummer: - Start- / Endseite: 199 - 214 Identifikator: Anderer: 1867-1381
CoNE: https://pure.mpg.de/cone/journals/resource/1867-1381