日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Sample preparation of biological macromolecular assemblies for the determination of high-resolution structures by cryo-electron microscopy.

Stark, H., & Chari, A. (2016). Sample preparation of biological macromolecular assemblies for the determination of high-resolution structures by cryo-electron microscopy. Microscopy, 65(1), 23-34. doi:10.1093/jmicro/dfv367.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
2249146.pdf (出版社版), 2MB
 
ファイルのパーマリンク:
-
ファイル名:
2249146.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (UNKNOWN id 303; )
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Stark, H.1, 著者           
Chari, A.1, 著者           
所属:
1Research Group of 3D Electron Cryo-Microscopy, MPI for biophysical chemistry, Max Planck Society, ou_578577              

内容説明

表示:
非表示:
キーワード: Cryo-EM; biochemistry; high-resolution; macromolecular complexes; sample optimization
 要旨: Single particle cryo-EM has recently developed into a powerful tool to determine the 3D structure of macromolecular complexes at near-atomic resolution, which allows structural biologists to build atomic models of proteins. All technical aspects of cryo-EM technology have been considerably improved over the last two decades, including electron microscopic hardware, image processing software and the ever growing speed of computers. This leads to a more widespread use of the technique, and it can be anticipated that further automation of electron microscopes and image processing tools will soon fully shift the focus away from the technological aspects, onto biological questions that can be answered. In single particle cryo-EM, no crystals of a macromolecule are required. In contrast to X-ray crystallography, this significantly facilitates structure determination by cryo-EM. Nevertheless, a relatively high level of biochemical control is still essential to obtain high-resolution structures by cryo-EM, and it can be anticipated that the success of the cryo-EM technology goes hand in hand with further developments of sample purification and preparation techniques. This will allow routine high-resolution structure determination of the many macromolecular complexes of the cell that until now represent evasive targets for X-ray crystallographers. Here we discuss the various biochemical tools that are currently available and the existing sample purification and preparation techniques for cryo-EM grid preparation that are needed to obtain high-resolution images for structure determination.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2015-12-152016-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1093/jmicro/dfv367
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Microscopy
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 65 (1) 通巻号: - 開始・終了ページ: 23 - 34 識別子(ISBN, ISSN, DOIなど): -