  MR-based axial field-of-view extension: Bipolar dual-echo spin echo imaging using automatically optimized readout gradients

Blumhagen, J., Ladebeck, R., Fenchel, M., & Scheffler, K. (2011). MR-based axial field-of-view extension: Bipolar dual-echo spin echo imaging using automatically optimized readout gradients. Poster presented at 28th Annual Scientific Meeting ESMRMB 2011, Leipzig, Germany.

Item is

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Blumhagen, JO, Autor
Ladebeck, R, Autor
Fenchel, M, Autor
Scheffler, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose/Introduction: Extended field-of-view (FoV) imaging is relevant for many applications, e.g. whole-body MR/PET attenuation correction [1], radiotherapy [2], and biopsy. Recently, a method to extend the axial FoV using an optimal readout (RO) gradient to compensate gradient nonlinearities and B0 inhomogeneities has been shown [3]. However, the optimal RO gradient depends on the position of the region of interest and therefore differs for optimization of the left and the right patient’s arm. In this work we developed a 2D SE-based sequence using a dual-echo acquisition with optimized RO gradients for distortion-reduced imaging of both the left and the right patient’s arm. Subjects and Methods: A dual-echo SE sequence was modified to handle RO gradients differing in polarity and amplitude (FIG. 1A). An additional prephase moment ensures the spin echo condition for the second echo. The readout gradients have been adapted to acquire a distortion-reduced axial slice of the right patient’s arm in the first echo and of the left patient’s arm in the second echo. The optimal space-depending RO gradients were calculated automatically by the sequence according to GRO (x,y,z) = - δB0(x,y,z) / c(x,y,z), where δB0 is the B0 inhomogeneity and c is the relative error in the gradient field. The main magnetic field inhomogeneities and the gradient field nonlinearities were measured using a magnetic probe array as described in [3]. The field coefficients were stored in spherical harmonics as input files for the sequence calculation. A volunteer experiment was performed on a 3T whole-body system, and a transversal slice at z=0 was acquired. The field-of-view was set to 600mm with 1.18*1.18mm in-plane resolution and 5mm slice thickness.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-011-0268-5
BibTex Citekey: BlumhagenLFS2011_2
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 28th Annual Scientific Meeting ESMRMB 2011
Veranstaltungsort: Leipzig, Germany
Start-/Enddatum: 2011-10-06 - 2011-10-08

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : No longer published by Elsevier
Seiten: - Band / Heft: 24 (Supplement 1) Artikelnummer: - Start- / Endseite: 431 Identifikator: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532